Sharp R-9200 Service Manual

Text of Sharp R-9200 Service Manual

In interests of user-safety

the oven should be restored to its original condition and only manufacturer original spare parts must be used. (RD161OlU) This is a supplemental Service Manual for Model R-9ZOO. This model is quite similar to Base Model R-9HlO (Refer No. is S9808R9HlOJ//). Use this supplemental manual together with the Base Model Service Manual. Refer to the Base Model

2. Oven lamp

3. Hinges 4. Safety door latches 5. See through door 6. Door open button 7. Touch Control Panel 8. Digital readout 9. Waveguide cover lO.Access cover for oven lamp replacement ll.Menue Label for Intelli- gent Sensor 12.Low rack 13.High rack 14.Defrost rack Convection I CONV AUTO COOK+j Fan Symbol Micro/Defrost Symbol MIX SENSOR DEFROST TEMP Indicator WEIGHT ADJUST PAD Press to zero the your own d

has been prepared to provide

Sharp Corp. Service engineers with Operation and Service Information. It is recommended that service engineers carefully study the entire text of this manual and base model manual, so they will be qualified to render satisfactory customer service. r- (RD36106 CAUTION MICROWAVE RADIATION Service engineers should not be exposed to the

Single phase, 3 wire earthed

16OOW (Microwave) 1600W (Convection) 800 watts nominal of RF microwave energy (2 litre water load) 900 watts (I EC-705-1 988) Operating frequency of 2450M Hz 1500 w Width 627 mm Height 378 mm Depth 481 mm Cooking Cavity Dimensions Width 410 mm Height 245 mm De

Sharp R-9200 or the absolute

hu- midity sensor (AH sensor) cooking condition. Weight sensor cooking condition. 1. The oven detects the weight of food automatically when food is placed into the oven. 2. The oven sets the cooking condition and cooking time automatically when the food category is inputted. 3. The oven starts cook

1. When the food

is placed on the turntable, the gap between the elctrodes increases in direct pro- portional to the weight of food. The elctrodes have the function of a capacitor. 2. The frequency of the oscilator changes according to the capacitance of the weight sensor. 3. The micro-computer meas- ures the weight of food by detecting

capable of producing

very high voltage and current, contact with any part of the high voltage circuit will result in electrocuition. REMEMBER TO CHECK 3D 1) Disconnect the supply. 2) Door opened, an.d wedged open. 3) Discharge high voltage capacitor. WARNING AGAINST THE CHARGE OF THE HIGH-VOLTAGE CAPACITOR The high-voltage capacitor remains charged about 60 seconds after the ov

- t 3

T 0 E - H i7 . ii ii I OT R - - - - - - - - - - - - I z - i ii fi E - - - I d - - - - - - - - - - L - - - - - - ? - ;I F? &I ! ii E k - - - - k - - - - - - - - - - - - - - - - - FE - z NR ;f it E kz i - - - - - 2 x - z E p: rsl ii - - - - - 1 T - : f E P; z F - - - -

Sharp R-9200 RE = Replace / CK = Check

=I a Li i Fi i $ PI - - - - - - - - - - - Ei? - t E E $ : LT E T - - - r L - - - - - - - - - - - - - E - 8: wk 52 EE R z ; $ - - ~ - - - - - CK - z 8; yi E N ;ig ii! 2 : - - - - - 3 - - - - - - - - - - - - - - T - - - - - - - - - - I ---I --r-r - - - - - - - - i 0 - ER 4 Y! d, - - - - - - - - - - I : -J 0 - FI t! F A - - - - - - 1 A 52 - 1 E !f R i - - 3 ? d - 3 - 1 - 3 - 1 1 1 I 1 > 77 - F ii T Es F iz 2 : ii! L Y - - -

Sharp R-9200 ’ NEVER TOUCH ANY PART IN THE CIRCUIT

WITH YOUR HAND OR AN INSULATED !- TOOL WHILE THE OVEN IS IN OPERATION. -1 ----- CARRY OUT 3D CHECKS Isolate the magnetron from the high voltage circuit by removing all leads connected to the filament terminal. To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron filament terminals, the meter should

Heat up for 1 min. 45 sec.

(RD82A02U) MICROWAVE OUTPUT POWER (IEC-7054988) The following test procedure should be carried out with the microwave oven in a fully assembled condition (outer case fitted). Microwave output power from the magnetron can be measured by way of IEC 705, i.e. it can be measured by using water load how much it can be absorbed by the water load.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tl

= 1 1 “C Temperature after (47 + 2) = 49 sec. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sharp R-9200 Remove the outer case and check voltage

between Pin Numbers 1 and 3 of the 3-pin connector (A) on the control unit with an A.C. voltmeter. The meter should indicate 240 volts, if not check oven circuit. Shut-off,Cook and Heater Relay Test These relays are operated by D.C. voltage. Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking or convection cooking o

or IC3, carry

out the following procedure in order to calibrate the weight sensor. food mav be over or under cooked. If the weight sensor is not recalibrate, the The following procedure should be carried out with microwave oven in a fully assembled condi- tion (with outer case fitted). 1. Place the turnrable on the turnt

of the following

units as shown in the touch control panel circuit. (1) Key Unit (2) Control Unit The principal functions of these units and the signals communicated among them are explained below. Key Unit The key unit is composed of a matrix, signals generated in the LSI are sent to the key unit through POO,PO5,PlO,P13,P14,P22,P23 and P25.. When a key pad is to

The I/O signals of the LSI(IZA413DR)

are detailed in the following table. PIN NO. 1 1 1 SIGNAL / VREF I I/O IN Reference voltage input terminal. A reference voltage applied to the A/D converter in the LSI. Connected to GND.(OV) (RD93GA6U) PIN NO. 1 2 1 SIGNAL / IN7 I I/O 1 IN Terminal to change cooking constant. PIN NO. 1 3 Signal similar to IN7 1 SIGNAL j IN6 I I/O / IN PIN NO. / 4 1 SIGNAL j IN5 I I/O j IN Signal similar

To turn on and off the cook relay( RY2).

In high operation, the signals holds “L” level during microwave cooking and “H” level while not cooking. In other cooking modes (MED HIGH, MED, MED LOW, LOW) the signal turns to “H” level and “L” level in repetition according to the power level. I I/O / OUT H’GH L MED HIGT+z{ MEP 3” lEr*c. J-J-i_ ME-) Low~lz’dpT-i_ PIN N

This is basic timing for all real time processing

of LSI. ti rnGND 1 20 msac PIN NO. j 25 1 SIGNAL / P30 I- I I/O 1 OUT Damper motor relay drivinq siqnal. To turn on and off the shut-off relay( RY4). OFF H GND ON , ---e--L PIN NO. / 26 Connected to VC. 1 SIGNAL ) CNVSS I I/O 1 IN (RD93KA3U) PIN NO. 1 27 1 SIGNAL 1 RESET I I/O ) IN Auto clear terminal.

signals and indicators

are as follows: I I/O j OUT Signal Segment Sianal Segment PI6 ..................................... LB2 PO2 .......................................... g PI4 .................................... UB2 PO1 ........................................... f PI 3 ..................................... LB1 PO0 ........

Signal similar to PI 5.

I I/O 1 OUT CRD938A2U) PIN NO. / 49 1 SIGNAL / PO5 I I/O j OUT Segment data signal. Signal similar to PI 6. Kev strobe signal. Signal applied to touch-key section. A pulse signal is input to RO-R3 terminal while one of G-8 line keys on key matrix is touched. (RD939A3U) PIN NO. 1 50 1 SIGNAL 1 PO4 I I/O / OUT Segment data siwal. Signal similar to P16. (RD939A2U) PIN NO. 1 51 Digit s

Sharp Microwave Oven Owners Instructions: