Text of iRobot CREATE OPEN Manual
iRobot Create Open Interface (OI) Specification
iRobot Create® Open Interface Overview..................................................3
Physical Connections...............................................................................4
Mini-DIN Connector................................................................................4
Cargo Bay Connector.............................................................................4
Serial Port Settings
iRobot Create Open Interface (OI) Specification iRobot Create® Open Interface
Overview
The Create Open Interface (OI) consists of an electronic
interface and a software interface for controlling Create’s
behavior and reading its sensors. The electronic interface
includes a 7 pin Mini-DIN connector and a DB-25 connector
in the Cargo Bay for connecting hardware and electronics
for sensors and actuators such as a robotic arm or light
sensor to Create. Th
iRobot Create Open Interface (OI) Specification To use the OI, a processor capable of generating serial
commands such as a PC or a microcontroller must be
connected to the external Mini-DIN connector or the
Cargo Bay Connector on Create. These connectors provide
two-way, serial communication at TTL (0 – 5V) levels. The
connectors also provide an unregulated direct connection
to iRobot Create’s battery, which you can use to power
the OI applications.
iRobot Create Open Interface (OI) Specification Baud: 57600 or 19200 (see below)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
By default, iRobot Create communicates at 57600 baud.
If you are using a microcontroller that does not support
57600 baud, there are two ways to force Create to switch
to 19200:
Method 1:
When powering on Create, hold down the Play button.
After about 4 seconds, Create plays a tune of descending
pitches. Create will c
iRobot Create Open Interface (OI) Specification The Create OI has four operating modes: Off, Passive,
Safe, and Full. After a battery change or when is first
supplied, the OI is in “off” mode. When it is off, the OI listens
at the default baud rate (57600 or 19200 - see Serial Port
Settings above) for an OI Start command. Once it receives
the Start command, you can enter into any one of the four
operating modes by sending a mode command to the OI.
Yo
iRobot Create Open Interface (OI) Specification The following is a list of all of iRobot Create’s Open Interface
commands. Each command starts with a one-byte opcode.
Some of the commands must be followed by data bytes.
All of Create’s OI commands including their required data
bytes are described below.
NOTE: Always send the required number of data bytes for
the command, otherwise, the processor will enter and
remain in a “waiting” state until al
iRobot Create Open Interface (OI) Specification Demo Commands
The following are commands to start iRobot Create’s
built-in demos.
Demo
Opcode: 136
Data Bytes: 1
This command starts the requested built-in demo.
• Serial sequence: [136][Which-demo]
• Available in modes: Passive, Safe, or Full
• Changes mode to: Passive
• Demo data byte 1: Demo number (-1 - 9)
Demo Names, Descriptions and Numbers
Number
Demo
Description
-1 (255)
Abort current demo
iRobot Create Open Interface (OI) Specification Actuator Commands
The following commands control iRobot Create’s actuators:
wheels, speaker, LEDS, digital outputs and low side
driver outputs.
Drive
Opcode: 137
Data Bytes: 4
This command controls Create’s drive wheels. It takes four
data bytes, interpreted as two 16-bit signed values using
two’s complement. The first two bytes specify the average
velocity of the drive wheels in millimeters per secon
iRobot Create Open Interface (OI) Specification Digital Outputs
Opcode: 147
Data Bytes: 1
This command controls the state of the 3 digital output
pins on the 25 pin Cargo Bay Connector. The digital outputs
can provide up to 20 mA of current.
• Serial sequence: [147] [Output Bits]
• Available in modes: Safe or Full
• Changes mode to: No Change
• Digital Outputs data byte 1: Output Bits (0 –7);
0 = low (0V); 1 = high (5V).
Example schematics
Vi
iRobot Create Open Interface (OI) Specification Send IR
Opcode: 151
Data Bytes: 1
This command sends the requested byte out of low side
driver 1 (pin 23 on the Cargo Bay Connector), using the
format expected by iRobot Create’s IR receiver. You must
use a preload resistor (suggested value: 100 ohms) in
parallel with the IR LED and its resistor in order turn it on.
• Serial sequence: [151][Byte Value]
• Available in modes: Safe or Full
• Changes m
iRobot Other Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
Command Module |
#LOSX38: Command Module Other Owner's manual |
34 | 1292 | 323 | 06-05-2026 | |
ROOMBA 5105 |
#ST34I1: ROOMBA 5105 Other Owner's manual |
105 | 1255 | 314 | 05-10-2026 | |
ROOMBA 5107 |
#4P3RTC: ROOMBA 5107 Other Owner's manual |
24 | 391 | 75 | 15-07-2026 | |
CREATE OPEN |
iRobot CREATE OPEN Guide (Manual ), @7ZT46T |
25 | 810 | 171 | 14-04-2026 | |
CREATE |
PDF Manual (@71IKHS), iRobot CREATE Other (24-07-2026) |
20 | 1329 | 319 | 24-07-2026 | |
DIRT DOG - 2 |
Other #22121L |
18 | 1011 | 243 | 03-09-2026 | |
SCOOBA 385 |
PDF User Guide (@LAD11I), iRobot SCOOBA 385 Other (03-07-2026) |
286 | 360 | 72 | 03-07-2026 | |
DISCOVERY SE |
#679CQ2: DISCOVERY SE Other Manual |
10 | 70 | 17 | 13-09-2026 | |
ROOMBA - SERIAL COMMAND INTERFACE |
Other #3H16OG |
10 | 1261 | 227 | 23-09-2026 |