iRobot CREATE OPEN Manual 

Brand: iRobot
Category: Other
Model: CREATE OPEN (Manual )
File Type: PDF
File Size: —
Pages: 25
Text of iRobot CREATE OPEN Manual 

iRobot Create Open Interface (OI) Specification

iRobot Create® Open Interface Overview..................................................3 Physical Connections...............................................................................4 Mini-DIN Connector................................................................................4 Cargo Bay Connector.............................................................................4 Serial Port Settings
iRobot Create Open Interface (OI) Specification iRobot Create® Open Interface Overview The Create Open Interface (OI) consists of an electronic interface and a software interface for controlling Create’s behavior and reading its sensors. The electronic interface includes a 7 pin Mini-DIN connector and a DB-25 connector in the Cargo Bay for connecting hardware and electronics for sensors and actuators such as a robotic arm or light sensor to Create. Th
iRobot Create Open Interface (OI) Specification To use the OI, a processor capable of generating serial commands such as a PC or a microcontroller must be connected to the external Mini-DIN connector or the Cargo Bay Connector on Create. These connectors provide two-way, serial communication at TTL (0 – 5V) levels. The connectors also provide an unregulated direct connection to iRobot Create’s battery, which you can use to power the OI applications.
iRobot Create Open Interface (OI) Specification Baud: 57600 or 19200 (see below) Data bits: 8 Parity: None Stop bits: 1 Flow control: None By default, iRobot Create communicates at 57600 baud. If you are using a microcontroller that does not support 57600 baud, there are two ways to force Create to switch to 19200: Method 1: When powering on Create, hold down the Play button. After about 4 seconds, Create plays a tune of descending pitches. Create will c
iRobot Create Open Interface (OI) Specification The Create OI has four operating modes: Off, Passive, Safe, and Full. After a battery change or when is first supplied, the OI is in “off” mode. When it is off, the OI listens at the default baud rate (57600 or 19200 - see Serial Port Settings above) for an OI Start command. Once it receives the Start command, you can enter into any one of the four operating modes by sending a mode command to the OI. Yo
iRobot Create Open Interface (OI) Specification The following is a list of all of iRobot Create’s Open Interface commands. Each command starts with a one-byte opcode. Some of the commands must be followed by data bytes. All of Create’s OI commands including their required data bytes are described below. NOTE: Always send the required number of data bytes for the command, otherwise, the processor will enter and remain in a “waiting” state until al
iRobot Create Open Interface (OI) Specification Demo Commands The following are commands to start iRobot Create’s built-in demos. Demo Opcode: 136 Data Bytes: 1 This command starts the requested built-in demo. • Serial sequence: [136][Which-demo] • Available in modes: Passive, Safe, or Full • Changes mode to: Passive • Demo data byte 1: Demo number (-1 - 9) Demo Names, Descriptions and Numbers Number Demo Description -1 (255) Abort current demo
iRobot Create Open Interface (OI) Specification Actuator Commands The following commands control iRobot Create’s actuators: wheels, speaker, LEDS, digital outputs and low side driver outputs. Drive Opcode: 137 Data Bytes: 4 This command controls Create’s drive wheels. It takes four data bytes, interpreted as two 16-bit signed values using two’s complement. The first two bytes specify the average velocity of the drive wheels in millimeters per secon
iRobot Create Open Interface (OI) Specification Digital Outputs Opcode: 147 Data Bytes: 1 This command controls the state of the 3 digital output pins on the 25 pin Cargo Bay Connector. The digital outputs can provide up to 20 mA of current. • Serial sequence: [147] [Output Bits] • Available in modes: Safe or Full • Changes mode to: No Change • Digital Outputs data byte 1: Output Bits (0 –7); 0 = low (0V); 1 = high (5V). Example schematics Vi
iRobot Create Open Interface (OI) Specification Send IR Opcode: 151 Data Bytes: 1 This command sends the requested byte out of low side driver 1 (pin 23 on the Cargo Bay Connector), using the format expected by iRobot Create’s IR receiver. You must use a preload resistor (suggested value: 100 ohms) in parallel with the IR LED and its resistor in order turn it on. • Serial sequence: [151][Byte Value] • Available in modes: Safe or Full • Changes m

iRobot Other Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
Command Module

#LOSX38: Command Module Other Owner's manual

34 1292 323 06-05-2026
ROOMBA 5105

#ST34I1: ROOMBA 5105 Other Owner's manual

105 1255 314 05-10-2026
ROOMBA 5107

#4P3RTC: ROOMBA 5107 Other Owner's manual

24 391 75 15-07-2026
CREATE OPEN

iRobot CREATE OPEN Guide (Manual ), @7ZT46T

25 810 171 14-04-2026
CREATE

PDF Manual (@71IKHS), iRobot CREATE Other (24-07-2026)

20 1329 319 24-07-2026
DIRT DOG - 2

Other #22121L

18 1011 243 03-09-2026
SCOOBA 385

PDF User Guide (@LAD11I), iRobot SCOOBA 385 Other (03-07-2026)

286 360 72 03-07-2026
DISCOVERY SE

#679CQ2: DISCOVERY SE Other Manual 

10 70 17 13-09-2026
ROOMBA - SERIAL COMMAND INTERFACE

Other #3H16OG

10 1261 227 23-09-2026

Other: Similar Manuals