iRobot ROOMBA - SERIAL COMMAND INTERFACE Serial Command Interface

(SCI) Specification © 2005 iRobot Corporation. All rights reserved. iRobot and Roomba are registered trademarks of iRobot Corporation. www.irobot.com

iRobot ROOMBA - SERIAL COMMAND INTERFACE iRobot® Roomba® Serial Command Interface (SCI) Specification

www.irobot.com SCI Overview Versions of iRobot® Roomba® Vacuuming Robot manufactured after October, 2005 contain an electronic and software interface that allows you to control or modify Roomba’s behavior and remotely monitor its sensors. This interface is called the iRobot Roomba Serial Command Interface or Roomba SCI. Roomba SCI is a serial protocol that allows users to control a Roomba
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com SCI Modes The Roomba SCI has four operating modes: off, passive, safe, and full. On a battery change or other loss of power, the SCI will be turned off. When it is off, the SCI will listen at the default baud bps for an SCI Start command. Once it receives the Start command, the SCI will be enabled in passive mode. In passive mode, users can do the following: • Request and re
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com Safe Command opcode: 131 Number of data bytes: 0 This command puts the SCI in safe mode. The SCI must be in full mode to accept this command. Note: In order to go from passive mode to safe mode, use the Control command. Serial sequence: [131] Full Command opcode: 132 Number of data bytes: 0 Enables unrestricted control of Roomba through the SCI and turns off the safety features
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com Leds data byte 2: Power Color (0 – 255) 0 = green, 255 = red. Intermediate values are intermediate colors. Leds data byte 3: Power Intensity (0 – 255) 0 = off, 255 = full intensity. Intermediate values are intermediate intensities. Example: To turn on the dirt detect and spot LEDs, make the status LED red, and to light the power LED green at half intensity, send the serial
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com Play Command opcode: 141 Number of data bytes: 1 Plays one of 16 songs, as specified by an earlier Song command. If the requested song has not been specified yet, the Play command does nothing. The SCI must be in safe or full mode to accept this command. This command does not change the mode. Serial sequence: [141] [Song Number] Play data byte 1: Song Number (0 – 15) Specifie
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com Roomba SCI Sensor Packets The robot will send back one of four different sensor data packets in response to a Sensor command, depending on the value of the packet code data byte. The data bytes are specified below in the order in which they will be sent. A packet code value of 0 sends all of the data bytes. A value of 1 through 3 sends a subset of the sensor data. Some of the s
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com Remote Control Command Packet subset: 2 Range: 0 – 255 (with some values unused) Data type: 1 byte, unsigned The command number of the remote control command currently being received by Roomba. A value of 255 indicates that no remote control command is being received. See Roomba remote control documentation for a description of the command values. Buttons Packet subset: 2 Ran
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com Baud data byte 1: Baud Code (0 – 9) Baud code Baud rate in bps 0 300 1 600 2 1200 3 2400 4 4800 5 9600 6 14400 7 19200 8 28800 9 38400 10 57600 11 115200 Motors data byte 1: Motor Bits 0 = off, 1 = on Bit 7 6 5 4 3 2 1 0 Motor n/a n/a n/a n/a n/a Main Brush Vacuum Side Brush Leds data byte 1: Led Bits (0 – 63) Dirt Detect uses a blue LED: 0 = off, 1 = on Spot, Clean, and Ma
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com Roomba SCI Sensors Quick Reference Packet Code Packet Size 0 26 bytes 1 10 bytes 2 6 bytes 3 10 bytes Name Groups Bytes Value Range Units Bumps Wheeldrops 0, 1 1 0 – 31 Wall 0, 1 1 0 – 1 Cliff Left 0, 1 1 0 – 1 Cliff Front Left 0, 1 1 0 – 1 Cliff Front Right 0, 1 1 0 – 1 Cliff Right 0, 1 1 0 – 1 Virtual Wall 0, 1 1 0 – 1 Motor Overcurrents 0, 1 1 0 – 31 Dirt De

iRobot Other Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
ROOMBA 5107

ROOMBA 5107 (Other ePDF User Guide, #U53EG9)

24 304 67 30-09-2026
Command Module

User Guide: iRobot Command Module (ZOHK46, Upd.19-09-2026)

34 213 49 19-09-2026
CREATE

iRobot Other Owner's manual (File: PDF, 29-08-2026)

20 94 16 29-08-2026
ROOMBA 5105

iRobot ROOMBA 5105 Guide (Owner's manual), @UN45L7

105 1284 206 09-05-2026
DISCOVERY SE

PDF User Manual (@A3X9U2), iRobot DISCOVERY SE Other (28-09-2026)

10 1381 291 28-09-2026
SCOOBA 385

#4R1LP7: SCOOBA 385 Other Manual 

286 571 115 07-08-2026
DIRT DOG - 2

#1H23DX: DIRT DOG - 2 Other Owner's manual

18 1410 297 28-09-2026
ROOMBA - SERIAL COMMAND INTERFACE

Other #288L16

10 1272 255 27-04-2026
CREATE OPEN

PDF Guide (@3LU78C), iRobot CREATE OPEN Other (05-08-2026)

25 1124 214 05-08-2026

Other: Similar Manuals