iRobot ROOMBA - SERIAL COMMAND INTERFACE Specification
| Brand: | iRobot |
| Category: | Other |
| Model: | ROOMBA - SERIAL COMMAND INTERFACE (Specification) |
| File Type: | |
| File Size: | — |
| Pages: | 10 |
Text of iRobot ROOMBA - SERIAL COMMAND INTERFACE Specification
iRobot ROOMBA - SERIAL COMMAND INTERFACE Serial Command Interface
(SCI) Specification
© 2005 iRobot Corporation. All rights reserved. iRobot and Roomba are registered trademarks of iRobot Corporation.
www.irobot.com
iRobot ROOMBA - SERIAL COMMAND INTERFACE iRobot® Roomba® Serial Command Interface (SCI) Specification
www.irobot.com
SCI Overview
Versions of iRobot® Roomba® Vacuuming Robot manufactured
after October, 2005 contain an electronic and software interface
that allows you to control or modify Roomba’s behavior and
remotely monitor its sensors. This interface is called the iRobot
Roomba Serial Command Interface or Roomba SCI.
Roomba SCI is a serial protocol that allows users to control a
Roomba
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com
SCI Modes
The Roomba SCI has four operating modes: off, passive, safe,
and full. On a battery change or other loss of power, the SCI will
be turned off. When it is off, the SCI will listen at the default
baud bps for an SCI Start command. Once it receives the Start
command, the SCI will be enabled in passive mode. In passive
mode, users can do the following:
• Request and re
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com
Safe
Command opcode: 131
Number of data bytes: 0
This command puts the SCI in safe mode. The SCI must be in
full mode to accept this command.
Note: In order to go from passive mode to safe mode, use the Control
command.
Serial sequence: [131]
Full
Command opcode: 132
Number of data bytes: 0
Enables unrestricted control of Roomba through the SCI and
turns off the safety features
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com
Leds data byte 2: Power Color (0 – 255)
0 = green, 255 = red. Intermediate values are intermediate
colors.
Leds data byte 3: Power Intensity (0 – 255)
0 = off, 255 = full intensity. Intermediate values are intermediate
intensities.
Example:
To turn on the dirt detect and spot LEDs, make the status
LED red, and to light the power LED green at half intensity,
send the serial
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com
Play
Command opcode: 141
Number of data bytes: 1
Plays one of 16 songs, as specified by an earlier Song
command. If the requested song has not been specified yet,
the Play command does nothing. The SCI must be in safe or full
mode to accept this command. This command does not change
the mode.
Serial sequence: [141] [Song Number]
Play data byte 1: Song Number (0 – 15)
Specifie
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com
Roomba SCI Sensor Packets
The robot will send back one of four different sensor data
packets in response to a Sensor command, depending on the
value of the packet code data byte. The data bytes are specified
below in the order in which they will be sent. A packet code value
of 0 sends all of the data bytes. A value of 1 through 3 sends a
subset of the sensor data. Some of the s
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com
Remote Control Command
Packet subset: 2
Range: 0 – 255 (with some values unused)
Data type: 1 byte, unsigned
The command number of the remote control command currently
being received by Roomba. A value of 255 indicates that no
remote control command is being received. See Roomba remote
control documentation for a description of the command values.
Buttons
Packet subset: 2
Ran
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com
Baud data byte 1: Baud Code (0 – 9)
Baud code
Baud rate in bps
0
300
1
600
2
1200
3
2400
4
4800
5
9600
6
14400
7
19200
8
28800
9
38400
10
57600
11
115200
Motors data byte 1: Motor Bits
0 = off, 1 = on
Bit
7
6
5
4
3
2
1
0
Motor
n/a
n/a
n/a
n/a
n/a
Main
Brush
Vacuum
Side
Brush
Leds data byte 1: Led Bits (0 – 63)
Dirt Detect uses a blue LED: 0 = off, 1 = on
Spot, Clean, and Ma
iRobot® Roomba® Serial Command Interface (SCI) Specification www.irobot.com
Roomba SCI Sensors Quick Reference
Packet Code
Packet Size
0
26 bytes
1
10 bytes
2
6 bytes
3
10 bytes
Name
Groups
Bytes
Value Range
Units
Bumps Wheeldrops
0, 1
1
0 – 31
Wall
0, 1
1
0 – 1
Cliff Left
0, 1
1
0 – 1
Cliff Front Left
0, 1
1
0 – 1
Cliff Front Right
0, 1
1
0 – 1
Cliff Right
0, 1
1
0 – 1
Virtual Wall
0, 1
1
0 – 1
Motor Overcurrents
0, 1
1
0 – 31
Dirt De
iRobot Other Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
ROOMBA 5107 |
ROOMBA 5107 (Other ePDF User Guide, #U53EG9) |
24 | 304 | 67 | 30-09-2026 | |
Command Module |
User Guide: iRobot Command Module (ZOHK46, Upd.19-09-2026) |
34 | 213 | 49 | 19-09-2026 | |
CREATE |
iRobot Other Owner's manual (File: PDF, 29-08-2026) |
20 | 94 | 16 | 29-08-2026 | |
ROOMBA 5105 |
iRobot ROOMBA 5105 Guide (Owner's manual), @UN45L7 |
105 | 1284 | 206 | 09-05-2026 | |
DISCOVERY SE |
PDF User Manual (@A3X9U2), iRobot DISCOVERY SE Other (28-09-2026) |
10 | 1381 | 291 | 28-09-2026 | |
SCOOBA 385 |
#4R1LP7: SCOOBA 385 Other Manual |
286 | 571 | 115 | 07-08-2026 | |
DIRT DOG - 2 |
#1H23DX: DIRT DOG - 2 Other Owner's manual |
18 | 1410 | 297 | 28-09-2026 | |
ROOMBA - SERIAL COMMAND INTERFACE |
Other #288L16 |
10 | 1272 | 255 | 27-04-2026 | |
CREATE OPEN |
PDF Guide (@3LU78C), iRobot CREATE OPEN Other (05-08-2026) |
25 | 1124 | 214 | 05-08-2026 |