GRASS VALLEY JUPITER LCD16 Datasheet

Text of the manual

product data sheet

Multiple mode capability with assignable and auto-relegending LCD buttons makes the LCD16 and LCD48 panels the choice for maximum flexibility. KEY FEATURES Jupiter LCD16 & LCD48 Control Panels The Jupiter™ LCD16 and LCD48 control panels are an attractive option to help you meet your workflow demands and introduce maximum flexibility into your routing infrastructure. Multiple Mode Capability These LCD control panels offer a wide range of operating modes to fit the needs of any routing environment. XY Mode – For simple source-to- destination switching. Single Destination Mode – Switch any destination available to the destination you need. Multiple Destination Mode – Switch any source to many destinations at once. Category Entry Mode – Select destinations or sources quickly and efficiently. Level Mode – For simple or complex breakaways. BPS Mode – Combine sources and destinations on one page. Exceeding Your Routing Needs When the scroll wheel is used, the buttons will automatically re-label to display the next page of items. Need to status multiple pages of destinations? Done. Each panel can status up to 16 or 48 destinations at a time and provide complete status for each destination including current source with lock, protect, or tie line status. Need to have access to all of the sources in the router? Done. Scroll through the entire router up to 16 or 48 sources at a time. Need to perform complex breakaway switching with easy to read status for all levels? Done. The level mode will display all levels associated with each destination and display the current source and lock or protect status of each level. Need to combine sources and destinations on one page? Done. The BPS mode allows each panel to display the desired combination of sources and destinations for maximum customization. The Flexibility of Dynamic LCD Button Technology The Jupiter LCD16 and LCD48 control panels offer you the freedom of changing pages of destinations, sources, levels, sequences (salvos), or overrides with a simple and easy scroll wheel, while each button’s status is updated quickly and dynamically. Complete and Easy-to-Understand Dynamic Status Display If destinations are protected or locked the associated button will change color to magenta or red respectively, and the button will display which panel owns the protect or lock function. If a route is using a tie line from another router the source will display a “T” above the source name. Each button is capable of displaying three lines of text with eight characters each. A typical button layout would be: Line 1 – Misc. Status Lock/Protect Tie Lines Line 2 – Current Source Line 3 – Current Destination Multiple operating modes: • The LCD panels allow you to change — — the way each panel operates right from the panel LAN- or WAN-capable: • Connect with an Ethernet connection — — and the panels will operate over your LAN or WAN View status of up to 48 destinations • at once: Each button can display status for — — individual destinations Status current source — — Status current level information — — Lock or protect status — — Tie line information — — Lock or protect destinations: • Lock and protect functions allow you — — to lock or protect all or individual levels Follows the Jupiter easy-to- • understand color code: Yellow for destinations — — Green for sources — — Amber for levels — — Red for lock — — Magenta for protect — —

product data sheet

Our customer support and professional services offerings ensure optimal system performance and maximize uptime. These services include call centers staffed around the clock, commissioning, professional training courses, and technical maintenance programs and service agreements. www.grassvalley.com/support Customer Support & Professional Services Specifications Operating Modes: BPS – Single destination • BPS – Multiple destination • BPS – Sources and destinations on • one page Category entry • Level mode • Maximum number of sources: system limit Maximum number of destinations: system limit Total sources + destinations: system limit Breakaways: up to 96 levels Sequences: yes Overrides: yes Lock and protect: yes Menu modes: yes Gang switching: yes GPIO option: yes Mounting size: 19" 1 RU (LCD16), 2 RU (LCD48) Overall width: 483 mm Overall height: 76 mm Depth (AC version): 111 mm Depth (DC version): 35 mm Power consumption: 12W Voltage range: 100V to 240V Ordering Information LCD16 – Control Panel JUP-CP-LCD16-AC With AC power supply JUP-CP-LCD16-DC With DC power supply JUP-CP-LCD16-AC-GP With GPIO and AC power supply JUP-CP-LCD16-DC-GP With GPIO and DC power supply LCD48 – Control Panel JUP-CP-LCD48-AC With AC power supply JUP-CP-LCD48-DC With DC power supply JUP-CP-LCD48-AC-GP With GPIO and AC power supply JUP-CP-LCD48-DC-GP With GPIO and DC power supply Jupiter LCD16 Control Panel Jupiter LCD48 Control Panel © Copyright 2011 Grass Valley USA, LLC. All rights reserved. Grass Valley and Jupiter are trademarks of GVBB Holdings S.a.r.l. All other tradenames referenced are service marks, trademarks, or registered trademarks of their respective companies. Specifications subject to change without notice. RMC-4018D-2

Other Other Manuals