Bendix® Inlet Regulating Valve or IRV™ for Compressors

SD-01-3408 SAFETY VALVE OUTLET SPRING TURBOCHARGER SUPPLY PORT 3/4” NPT OUTLET FLANGE (MATES TO COMPRESSOR INLET) VENT MOUNTING HOLE VALVE SEAT O-RING CAP NUT O-RING SPACER FIGURE 1 - COMPRESSOR INLET REGULATING VALVE FIGURE 2 - INLET REGULATING VALVE DESCRIPTION The IRV™ inlet regulating valve is intended for use on multi-cylinder compressors which receive their induction air supply from t

FIGURE 3 - COMPRESSOR EITHER LOADED OR

UNLOADED WITH LOW TURBOCHARGER PRESSURE OUTLET TO COMPRESSOR temperature o-rings, seals, seats, and lubricant are used throughout the IRV™ valve to provide compatibility with incoming turbocharger air temperatures up to 250°F. The unitized valve and piston assembly consists of the piston housing, two o-rings and control piston with its permanently affixed valve plate. The cavity below the piston is vented to atm

BENDIX INLET REG VALVE COMP FIGURE 6 - SAFETY VALVE OPERATION

With the compressor unloaded air demand ceases and the IRV™ valve closes as turbo supply pressure exceeds 5 psi. The valve will close at a pressure between 5 and 10 psi and remain closed at higher pressures, allowing only a minute flow to compensate for compressor piston ring blow-by in the unloaded mode. At the compressor inlet, pressure is maintained at less than 10 psi. SAFETY VALVE OPERATION (Figure 6) If for any

FIGURE 8 - IRV™ VALVE TEST APPARATUS

OPERATION & LEAKAGE TESTS (Figures 7 & 8) GENERAL In order to test the operation of the IRV™ valve it will be necessary to install the equipment and apparatus as illustrated in Figure 8. The Bendix compressor inlet adapter in Figures 7 and 8 can be obtained at the nearest Bendix parts outlet. In most cases the inlet adapter will be required, however, if the IRV™ valve being tested has a 1/8 inch NPT access port

FIGURE 9 - INLET REGULATING VALVE

4. Adjust shop air to the IRV™ valve to 5 psi and allow the compressor to build the vehicle air system pressure to governor cut-out and note that the compressor unloads. With the compressor unloaded increase the shop air pressure to the IRV™ valve in 5 psi increments up to 25 psi. Pause 15-20 seconds at each pressure setting and note that the compressor inlet pressure as indicated by test gauge ‘A’ is 12 psi or

BW1552 © 2004 Bendix Commercial Vehicle Systems LLC All rights reserved. 3/2004 Printed in U.S.A.

CLEANING & INSPECTION 1. Using mineral spirits, clean and thoroughly dry all metal parts with the EXCEPTION of the VALVE AND PISTON ASSEMBLY. The valve and piston assembly contain o-rings, therefore, wipe the exterior of the exposed areas avoiding the bore in which the piston slides since a special high temperature lubricant is used on that surface. 2. Usi