BENDIX INLET REG VALVE COMP Manual
Text of BENDIX INLET REG VALVE COMP Manual
Bendix® Inlet Regulating Valve or IRV™ for Compressors
SD-01-3408
SAFETY
VALVE
OUTLET
SPRING
TURBOCHARGER
SUPPLY PORT 3/4” NPT
OUTLET FLANGE
(MATES TO
COMPRESSOR INLET)
VENT
MOUNTING
HOLE
VALVE SEAT
O-RING
CAP NUT
O-RING
SPACER
FIGURE 1 - COMPRESSOR INLET REGULATING VALVE
FIGURE 2 - INLET REGULATING VALVE
DESCRIPTION
The IRV™ inlet regulating valve is intended for use on
multi-cylinder compressors which receive their induction
air supply from t
FIGURE 3 - COMPRESSOR EITHER LOADED OR
UNLOADED WITH LOW TURBOCHARGER PRESSURE
OUTLET
TO
COMPRESSOR
temperature o-rings, seals, seats, and lubricant are used
throughout the IRV™ valve to provide compatibility with
incoming turbocharger air temperatures up to 250°F. The
unitized valve and piston assembly consists of the piston
housing, two o-rings and control piston with its permanently
affixed valve plate. The cavity below the piston is vented to
atm
BENDIX INLET REG VALVE COMP FIGURE 6 - SAFETY VALVE OPERATION
With the compressor unloaded air demand ceases and the
IRV™ valve closes as turbo supply pressure exceeds 5 psi.
The valve will close at a pressure between 5 and 10 psi and
remain closed at higher pressures, allowing only a minute
flow to compensate for compressor piston ring blow-by in
the unloaded mode. At the compressor inlet, pressure is
maintained at less than 10 psi.
SAFETY VALVE OPERATION (Figure 6)
If for any
FIGURE 8 - IRV™ VALVE TEST APPARATUS
OPERATION & LEAKAGE TESTS
(Figures 7 & 8)
GENERAL
In order to test the operation of the IRV™ valve it will be
necessary to install the equipment and apparatus as
illustrated in Figure 8.
The Bendix compressor inlet adapter in Figures 7 and 8 can
be obtained at the nearest Bendix parts outlet. In most cases
the inlet adapter will be required, however, if the IRV™ valve
being tested has a 1/8 inch NPT access port
FIGURE 9 - INLET REGULATING VALVE
4. Adjust shop air to the IRV™ valve to 5 psi and allow the
compressor to build the vehicle air system pressure to
governor cut-out and note that the compressor unloads.
With the compressor unloaded increase the shop air
pressure to the IRV™ valve in 5 psi increments up to 25
psi. Pause 15-20 seconds at each pressure setting and
note that the compressor inlet pressure as indicated by
test gauge ‘A’ is 12 psi or
BW1552 © 2004 Bendix Commercial Vehicle Systems LLC All rights reserved. 3/2004 Printed in U.S.A.
CLEANING & INSPECTION
1. Using mineral spirits, clean and thoroughly dry all metal
parts with the EXCEPTION of the VALVE AND PISTON
ASSEMBLY. The valve and piston assembly contain
o-rings, therefore, wipe the exterior of the exposed areas
avoiding the bore in which the piston slides since a
special high temperature lubricant is used on that
surface.
2. Usi