Testboy TV 450 Instruction Manual

Text of the manual

Beim Alten Flugplatz 3

D - 49377 Vechta Tel: 0049 (0)4441 / 89112-10 Fax: 0049 (0)4441 / 84536 www.testboy.de [email protected] Mark on your equipment certifies that this equipment meets the requirements of the EU (European Union) concerning safety and electromagnetic compatibility regul

TESTBOY TV 450

Table of contents 3 Table of contents 1 Preface ....................................................................................................................6 2 Safety and operational considerations.................................................................7 2.1 Warnings and notes ..................................................

TESTBOY TV 450

Table of contents 4 5.4.4 RCD Autotest ...........................................................................................40 5.5 Fault loop impedance and prospective fault current........................................43 5.6 Line impedance and prospective short-circuit current .....................................45 5.7 Earth resistan

TESTBOY TV 450

Table of contents 5 B Appendix B - Accessories for specific measurements .....................................72 C Appendix F – Country notes................................................................................73 C.1 List of country modifications ............................................................................73 C.2 Mo

TESTBOY TV 450

Preface 6 1 Preface Congratulations on your purchase of the TESTBOY instrument and its accessories from TESTBOY. The instrument was designed on a basis of rich experience, acquired through many years of dealing with electric installation test equipment. The TESTBOY instrument is professional, multifunctional, hand-held test instrument intended

TESTBOY TV 450

Warnings and notes 7 2 Safety and operational considerations 2.1 Warnings and notes In order to maintain the highest level of operator safety while carrying out various tests and measurements, TESTBOY recommends keeping your TESTBOY instruments in good condition and undamaged. When using the instrument, consider the following general warnings:

TESTBOY TV 450

Warnings and notes 8 Warnings related to measurement functions: Insulation resistance � Insulation resistance measurement should only be performed on de-energized objects! � Do not touch the test object during the measurement or before it is fully discharged! Risk of electric shock! � When an insulation resistance measurement has been

TESTBOY TV 450

Warnings and notes 9 Continuity functions � If voltages of higher than 10 V (AC or DC) is detected between test terminals, the continuity resistance test will not be performed. � Before performing a continuity measurement, where necessary, compensate test lead resistance. RCD functions � Parameters set in one function are also kept for o

TESTBOY TV 450

Battery and charging 10 2.2 Battery and charging The instrument uses six AA size alkaline or rechargeable Ni-Cd or Ni-MH battery cells. Nominal operating time is declared for cells with nominal capacity of 2100 mAh. Battery condition is always displayed in the lower right display part. In case the battery is too weak the instrument indicates t