REV 6.1.4 / PL-INSTL-WIRING-EN

Table of Contents © Copyright 2018 ProLon. All rights reserved. No part of this document may be photocopied or reproduced by any means, or translated to another language without prior written consent of ProLon. All specifications are nominal and may change as design improvements are introduced. ProLon shall not be liable ...

REV 6.1.4 / PL-INSTL-WIRING-EN

1 - PL-M2000 Unit Controller + PL-VC2000 Zone Controller(s) Recommended wiring for communication: #24/2, stranded, twisted and shielded, low-capacitance. Recommended wiring for 24vac supply: #18/2, stranded. *Connect “24VAC“ and “C” terminals to “R“ and “C“ terminals respectively on A/C control board. NET ...

REV 6.1.4 / PL-INSTL-WIRING-EN

2 - PL-NC2000 Network Controller + PL-M2000 Unit Controller(s) Recommended wiring for communication: #24/2, stranded, twisted and shielded, low-capacitance. Recommended wiring for 24vac supply: #18/2, stranded. *Connect “24VAC“ and “C” terminals to “R“ and “C“ terminals respectively on A/C control board. C ...

REV 6.1.4 / PL-INSTL-WIRING-EN

3 - PL-VC2000 Zone Controller + Digital Wall Sensor Recommended wiring for communication: #24/2, stranded, twisted and shielded, low-capacitance. Recommended wiring for 24vac supply: #18/2, stranded. 1 4 3 2 COM 24VAC INT B (-) INT A (+) NET A NET B Modbus BACnet VC2000 DIG OUT On/Off Pulse 24VAC COM COM AI www.prolon.net ...

REV 6.1.4 / PL-INSTL-WIRING-EN

4 - PL-M2000 Single-Zone Unit Controller + Digital Wall Sensor Recommended wiring for communication: #24/2, stranded, twisted and shielded, low-capacitance. Recommended wiring for 24vac supply: #18/2, stranded. *Connect “24VAC“ and “C” terminals to “R“ and “C“ terminals respectively on A/C control board. 2 ...

REV 6.1.4 / PL-INSTL-WIRING-EN

5 - PL-C1000 Single-Zone Controller + Digital Wall Sensor Recommended wiring for communication and 24vac supply: CAT5e cable + RJ45 connectors -OR- #18/4, stranded + PL-T1000-ADAPT STAT NETSND NETREC INTSND A NET B OCC SUPPLY GND SETPT ROOM + COM 24VAC COM 24VAC COM 24VAC COM 24VAC COM 24VAC COM INTREC HBEAT OUT5 OUT4 O ...