Cirrus SR22 Maintenance Manual

Text of the manual

C I R R U S A I R P L A N E M A I N T E N A N C E M A N U A L

M O D E L S R 2 2 24-00 Page 1 All EFFECTIVITY: ELECTRICAL POWER 1. GENERAL This chapter contains information on DC Generation, External Power, and Electrical Load Distribution. The airplane is equipped with a two-alternator, two-battery, 28-volt direct current (VDC) electrical system designe

C I R R U S A I R P L A N E M A I N T E N A N C E M A N U A L

M O D E L S R 2 2 15 Apr 2007 2. TROUBLESHOOTING Trouble Probable Cause Remedy No alternator output. (Voltmeter Indicates 24 VDC or less and the ammeter indicates a discharge when the corresponding BAT switch is set to ON position) Loose alternator wire connection

C I R R U S A I R P L A N E M A I N T E N A N C E M A N U A L

M O D E L S R 2 2 24-00 Page 3 All EFFECTIVITY: External power receptacle inoper- able. BAT 1 switch in OFF position. Set BAT 1 switch to ON position. Faulty ground wire/connection. Inspect and repair ground wire/ connection at receptacle or fire- wall ground bus bar. Faulty ground power relay

C I R R U S A I R P L A N E M A I N T E N A N C E M A N U A L

M O D E L S R 2 2 15 Apr 2007 Starter motor will not engage. Starter relay circuit breaker open. Reset starter relay circuit breaker. If starter relay circuit breaker opens on second attempt, check for wiring short between circuit breaker panel and MCU. Loose elec

C I R R U S A I R P L A N E M A I N T E N A N C E M A N U A L

M O D E L S R 2 2 24-00 Page 5 All EFFECTIVITY: Starter motor engages when BAT 1 master switch is set to ON posi- tion. MCU starter relay welded closed. MCU starter relay faulty. Return MCU to approved factory service center for service. Starter motor faulty. Replace starter motor. (Refer to 8

C I R R U S A I R P L A N E M A I N T E N A N C E M A N U A L

M O D E L S R 2 2 15 Apr 2007 Annunciator Panel ALT 2 shows steady illumination above 2200 RPM. ALT 2 circuit breaker open. Reset ALT 2 circuit breaker. MCU 14600-001, 14600-002, 16600-001: MCU logic module faulty. Perform Operational Inspection - Master Control U

C I R R U S A I R P L A N E M A I N T E N A N C E M A N U A L

M O D E L S R 2 2 24-00 Page 7 All EFFECTIVITY: Annunciator Panel LOW VOLTS illuminated. MCU 14600-001, 14600-002, 16600-001: Alternator switch faulty. Set BAT 1 switch to OFF position. At MCU, disconnect plug P108. Connect pin D of jack J108 to ground. If LOW VOLTS illuminates, a short exists

C I R R U S A I R P L A N E M A I N T E N A N C E M A N U A L

M O D E L S R 2 2 15 Apr 2007 Annunciator Panel ALT 2 flashing. MCU 14600-001, 14600-002, 16600-001: MCU logic module faulty. Perform Operational Inspection - Master Control Unit. If MCU Operational Inspection shows normal currents and volt- ages, set ALT 2 switch

C I R R U S A I R P L A N E M A I N T E N A N C E M A N U A L

M O D E L S R 2 2 24-00 Page 9 All EFFECTIVITY: Annunciator Panel or ALT 2 does not illuminate when ammeter shows no current. ALT 2 circuit breaker open. Reset ALT 2 circuit breaker. Loose electrical connections at MCU. Ensure all electrical connections at MCU are secure. MCU 14600-001, 14600-

Other Aircrafts Manuals