KERN PLS Manuals
KERN PLS Operating manual (78 pages)
- Identifier: id-995348
- Brand: KERN
- Device: KERN PLS Scales
- Type: Operating manual, PDF
- Key Aspects: Troubleshooting Information, Features vs. Competitors
- UPD Date: 02.04.2026
- Source File: 1163139.pdf
- Pages: 78
- Description: Essential instructions for the KERN PLS. The document details configuration and usage procedures, firmware installation, repair references, assembly reference.
Key Pages and Contents:
-
According to EU directive 90/384/EEC balances must be verified if they are used as
follows (legally controlled area): a) For commercial transactions if the price of goods is determined by weighing. b) For the production of medicines -
Contrast of the display
(see chap. 9.7) Contr 1-15 Select contrast Backlight (see chap. 9.8) Blt on Backlight on off Backlight off Auto Backlight automatically switched off 3 seconds after achieving stable weighing value. Changes in weight or pressing of keys will automa -
10.2.2 Determining density of liquids
Fill sample liquid into a vessel, e.g. a pitcher. Heat sample liquid until temperature is constant. Prepare a glass sinker with known density In weighing mode press MENU Press MENU button Acknowledge using PRINT button, the cur -
10.5 Percent determination
Percent determination allows weight display in percent, in relation to a reference weight. 10.5.1 Entering the reference weight by weighing In weighing mode press MENU Press MENU button repeatedly Acknowledge using PRINT button, the current
KERN PLS Operating manual (101 pages)
- Identifier: id-2157134
- Brand: KERN
- Device: KERN PLS Scales
- Type: Operating manual, PDF
- Key Aspects: Troubleshooting Information, Device Features Over Time
- UPD Date: 09.04.2026
- Source File: 2130501.pdf
- Pages: 101
- Description: Comprehensive setup guide for the KERN PLS. This documentation details procedures for operational safety, energy usage, technical troubleshooting, setup.
Key Pages and Contents:
-
Accurate setting and stable installation are the conditions enabling to obtain
repeatable results. Small unevenness or inclination of the base surface can be compensated by leveling the scale. • Level the scale using the leveling feet. The -
Using the navigation buttons , select the required multiplication factor.
1 = Single formulation amount 2 = Double formulation amount 3 = Triple formulation amount etc. Confirm the selected multiplication factor, pressing the PRINT button. Exam -
11.1 Weight units (unit1/unit2)
Weight units which are to be available during operation can be specified in the menu. After different units (unit1 and unit2) are selected, the weighing result can be displayed in two weight units (unit1 and unit2) simulta -
8.6 Adjustment report display/print
This function enables to print the report on the most recent adjustment. The scale and printer communication parameters must be compatible. Communication parameters, see chapter 11.2 and 11.3. Printout conforming to GLP
KERN PLS Operating instructions manual (34 pages)
- Identifier: id-962761
- Brand: KERN
- Device: KERN PLS Scales
- Type: Operating instructions manual, PDF
- Key Aspects: Practical Usage Examples, User Rights and Responsibilities, Customization Options
- UPD Date: 12.04.2026
- Source File: 1195745.pdf
- Pages: 34
- Description: Complete device guide for the KERN PLS. This guide provides technical guidance on support details, performance optimization, assembly reference.
Key Pages and Contents:
-
7.5 Parts counting
You are weighing e.g. 10 identical parts; i.e. the reference quantity is 10. The balance will automatically calculate the average weight per part. From now the pieces to be counted are displayed as number of parts. As a rule: The higher the reference quantity the higher the counti -
9.4.3 Output format
Stable values: 1 2 3 S CR LF 1 2 3 4 5 6 S B A B CR LF Display 0.000 g 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 8 19 20 S B B B + B B B B 0 0 0 0 B B g B CR LF Display 45,288 g 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 8 19 20 S B B B + B B B 4 5 2 8 8 B B g B CR LF Instable -
3 Fundamental information (general)
3.1 Intended Use The balance you have acquired serves to determine the weighing value of the material to be weighed. It is intended to be used as a “non-automatic“ balance, i.e. the material to be weighed is manually and carefully placed in the centre of the w -
7.1 Operating elements
7.1.1 Rear illuminated Display Contrasting display which can also be read in the dark. To choose the backlight mode, please follow the below instruction for the setting: Operation: Display: Ö Use the ON/OFF-button to turn on the balance 0.00g a Ö Press Tare-butto
PLS: Related Instructions from Other Manufacturers
-
HPI Racing micro RS4 Motorized Toy Car Instruction manual
36 -
Danfoss AMV 335 Controller Installation manual
14 -
Whirlpool LA5300XS Washer Use & care manual
16 -
Fisher-Price T4257 Baby & Toddler Furniture Operation & user’s manual
16 -
VTech TD45270194 - DECT 6.0 With 2 Handsets Telephone Operation & user’s manual
14 -
Hot Max ARC100 Welding System Operator's manual
8