IVAR EQUICALOR AS 1000 Manuals
1 pdf manual(s) IVAR EQUICALOR AS 1000 for free download (Document Types: Instruction sheet)
IVAR EQUICALOR AS 1000 Instruction sheet [PDF] (2 pages)
- Identifier: id-1566227
- Brand: IVAR
- Device: EQUICALOR AS 1000 Thermostat
- Type: PDF
- Key Aspects: Control Panel and Interface Navigation, Warranty and Service Information, Storage and Care Recommendations
- UPD Date: 11.06.2026
- Source File: 1435047.pdf
- Pages: 2
- Description: Essential instructions for the IVAR EQUICALOR AS 1000.
Click to expand and read text
9 9A EQUICALOR - AS 1000 INSTRUCTIONS SHEET AS1000 300538US-10-14 TECHNICAL CHARACTERISTICS TRANSMISSION • frequency: 915.00 MHz • Signal range: 33yd with no ob- stacles POWER SUPPLY • Voltage: 4.5 V • Type of batteries: 3 AA stylus alka- line batteries (mod. LR6) 1.5V • Battery life: 3 years (with brand new, well stored batteries and in op- timal operating conditions)* • Type of device: Digital electronic CONNECTION • Type of connection: M30x1.5 • Closing distance X: between 0.41 and 0.47 in; see figure 17 ENVIRONMENTAL CONDITIONS • Temperature limits for transport and storage: from -4°F to +130°F • Operating temperature limits: from 23°F to +110°F OVERALL DIMENSIONS (in) L=3.60, H=1.90, W=2.60 PRODUCT CODE • Description: axial servomotor • EQUICALOR-A: Art. AS 1000 - Code 506364US BATTERY STORAGE CONDITIONS • Temperature: 68 °F ensure long battery life SAFETY • Insulation: CLASS III CONTACTS IVAR US, Inc. Mailing Address: PO Box 8015, Elkridge, MD 21075 T: 1-855-9-IVAR-US www.ivar-us.com [email protected] I.V.A.R. S.p.A. Via IV Novembre, 181 25080 Prevalle (BS) - Italy T: +39 030 68028 - F: +39 030 6801329 www.ivar-group.com [email protected] CONDITIONS OF WARRANTY I.V.A.R. S.p.A. is insured against damage caused to third parties due to product manufacturing defects in accordance with the terms and limits set out in Legislative Decree 206/2005. The maximum insur- ance coverage is € 3,000,000.00 per claim, per year. The liability of IVAR for damages caused by defec- tive products is governed by the general sales conditions and by Legislative Decree 206/05 (art.114- 127) and is valid for 2 years after the product’s installation. I.V.A.R. S.p.A. ensures the compliance and the proper functioning of its products in accordance with the terms of Legislative Decree 206/05. ENGLISH CONTENTS OF THE PACKAGE • Actuator • Utility key *A • Stylus alkaline batteries • This Instructions sheet BATTERY REPLACEMENT The actuator requires 3 AA 1.5 V Alka- line batteries. The batteries must be inserted in order to operate the equipment. 1 To replace the batteries, use the utility key, supplied in the package. 2 Release the battery slide, inserting the utility key as indicated in Figure 2 . 3 Remove the battery housing slide and arrange the batteries in the order and direc- tion indicated on the bottom of the slide; see Figure 3 and 3A. 4 Reposition the slide, sliding it all the way until it clicks. NOTE: SEE THE MANUAL ATTACHED TO THE CHRONOTHERMOSTAT TO COMPLETE INSTALLATION. INSTALLATING THE ACTUATOR 5 Make sure to have installed the batteries. 6 Remove (with a small screwdriver) the fixing pin from upper numbered disc as in- dicated in the figure. 7 Press the utility key into the housing. 8 Fully open the actuator, slowly turning the key anti-clockwise until about 45° from the limit switch 8A, in order to align the pi- ston 8C with the minimum point. This point is indicated in the figure in detail 8D. Then remove the key. 9 Raise the connecting threaded ring nut 9A in the direction indicated. 10 Secure the actuator to the radiator ma- nually screwing down the threaded ring nut, tightening it with an appropriate size wrench. 11 Fully close the actuator, maintaining the front selector in position ’-’ until Led 4 flashes for the first time (See Figure above - ACTUA- TOR CONTROLS), which occurs after 5 seconds. Release the button after this signal. The si- multaneous rapid flashing of Leds 4, 5, and 6 indicates closure has occurred. 12 Remove the numbered disc located on the upper part of the actuator (See figure). 13 Put the numbered disc back in place, making sure the ‘0’ is aligned with the re- ference mark (*); then press the disc in the housing. 14 Put the fixing pin back in place. 15 To complete the assisted closure/ope- ning phase, the selector must be kept in the SELECT position until Leds 3 and 4 light up, which happens after 5 seconds. Release the button after this signal. 16 Proceed with associating the actuator and with the final test (SEE THE MANUAL AT- TACHED TO THE CHRONOTHERMOSTAT). LED 1 LED 2 LED 3 LED 4 LED 5 LED 6 FRONT SELECTOR Position ‘SELECT’ PRESS ACTUATOR CONTROLS Position ‘+’ PUSH UPWARDS Position ‘-’ PUSH DOWN- WARDS ( X ) MAX= 0.37 in MAX= Ø0.83 in M30x1,5 10 12 8A 7 6 8D OPEN THIS WAY 3 MIN MAX 8C 3A 17 2 * 13 14 *A FCC ID: 2AB4Y506364US This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including in- terference that may cause undesired operation. NOTE: this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide rea- sonable protection against harmful interference in a residential installation. This equipment ge- nerates, uses, and can radiate radio frequency energy and, if not installed and used in accor- dance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equip- ment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equip- ment and receiver. • Connect the equipment into an outlet on a cir- cuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. RF Exposure: this equipment complies with FCC radiation exposure limits set forth for an uncon- trolled environment. This equipment should be installed and operated with min. distance 20 cm between the radiator and your body. This trans- mitter must not be co-located or operating in conjunction with any other antenna or transmitter. Warning: Changes or modifications to this devi- ce not expressly approved by IVAR Spa could void the user’s authority to operate the equipment. * battery life may be shortened by bad RADIO transmission conditions (L SIGN), by the presence of obstacles or by storage conditions other than those prescribed. Batteries of different brands may have different behaviour and lower life than indicated in the present document.
EQUICALOR AS 1000: Related Instructions
300350-04-12 IC-BOX Manuale di istruzioni Instruction manual Manuel d’utilisation Bedienungsanleitung Manual de instrucciones Handleiding Product documentation for the IVAR IC-BOX 1 Controller. It covers topics such as system parameters, maintenance guidelines, operational procedures, detailing setup.
300451-04-17 Manuale di istruzioni Instruction manual EQUICOMPACT Instruction and reference manual for the IVAR EQUICOMPACT Control Unit. The manual provides information on network configuration, dimensions and layout, service instructions.
300349-04-12 IS-BOX Manuale di istruzioni Instruction manual Manuel d’utilisation Bedienungsanleitung Manual de instrucciones Handleiding Device operation guide for the IVAR IS-BOX Digital Manifolds. This manual outlines safety protocols, operating instructions, component overview, hardware setup.
9 9A EQUICALOR - AS 1000 INSTRUCTIONS SHEET AS1000 300538US-10-14 TECHNICAL CHARACTERISTICS TRANSMISSION • frequency: 915.00 MHz • Signal range: 33yd with n User support guide for the IVAR EQUICALOR AS 1000 Thermostat. This manual explains troubleshooting tips, hardware setup, installation, support details.
300349-04-12 IS-BOX Manual instructiuni Instruction Manual Operating instructions for the IVAR IS-BOX Plumbing Product. It provides technical information on troubleshooting guides, power management, usage tips, setup guidelines.
I.VAR INDUSTRY S.r.l. Via S. Pierino, 4 (Z.A.I.) - 37060 Trevenzuolo – VERONA - Italy Telefono 045/6680082 - Telefax 045/6680051 - P.IVA 02835480233 e-mail: i User documentation for the IVAR SUPERAC 93 Boiler. It explains usage scenarios and diagnostic information, service contacts, performance optimization, product specifications.
Similar Manuals in the Thermostat Category
8 Electronic programmable thermostat with microprocessor, with daily programming, to control heating and air- conditioning installations. Intellitherm C32 Daily Instruction reference guide for the Fantini Cosmi Intellitherm C32 Thermostat. This manual outlines device features, user settings, maintenance procedures, hardware components.
T1100 User Guide Ver. 5.1 Introduction The T1100 digital thermostats are networkable, microprocessor-based thermostats designed for zoning applications. Proport Professional manual for the Prolon T1100 Thermostat. It describes operating procedures and operating instructions, maintenance guidelines, installation steps.
Important Safety Information WARNING: • Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position bef Advanced user manual for the Robertshaw 9620 Thermostat. This guide describes performance guidelines, cleaning instructions, basic operation.
s Operating Instructions en RDG100T RDG160T RDG160TU RDG100T / RDG160T / RDG160TU – the electronic room thermostat that allows you to set the ideal room temp Complete instruction guide for the Siemens RDG100T Thermostat. It offers guidance on user preferences, configuration options, warranty information.