PDA Range PDA200/2 Installation Instructions Manual
Text of PDA Range PDA200/2 Installation Instructions Manual
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 1
PDA200/2, PDA500/2, PDA1000/2
INSTALLATION INSTRUCTIONS
This equipment must be installed by a suitably skilled and technically
competent person. Please read these instructions carefully before installation.
Important notes .......................................................................................... 2
What is an audio frequency induction loop system? ................
PDA Range PDA200/2 PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 2
Important notes
These instructions are general and cannot be considered to cover every aspect of
audio-frequency induction loop system design and installation.
We recommend you read BS7594 (The Code of Practice for Audio-Frequency Induction
Loop Systems) and EN60118-4 (Magnetic field strength in audio frequency induction loop
systems for hearing aid purposes), copies of which are
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 3
An audio-frequency induction loop system (AFILS) allows hearing impaired
people to hear more clearly.
Most hearing aids have a ‘T’ or ‘MT’ switch which allows them to pick up the
electromagnetic field generated by an induction loop system. The hearing aid
converts this signal into a sound suited to its user’s specific hearing requirements.
Any hearing impaired person pos
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 4
INPUT MODE SELECT SWITCH
Allows the MIC./LINE input to be configured for
Mic or Line operation and for optional 11V phantom
power to be switched to the inputs.
SW1
1
2
3
4
Familiarisation with your Pro-Range induction loop amplifier
MIC. INPUT
Accepts standard three-pin male XLR
type connectors. Optional 11V
phantom power is available via input
mode select switch 1.
MIC./LINE INPU
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 5
COMPRESSION INDICATORS
Give a visual indication of the amplifier’s compressor activity.
Installers should refer to these indicators when using the
amplifier’s input signal level controls.
For best results, we recommend you set the inputs so that
the LOW compression indicator is lit most of the time and
the HIGH compressor indicator illuminates only with peaks in
the input sign
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 6
Loop cable selection
Almost any single core tri-rated
cable can be used for the
induction loop provided it is of
the appropriate DC resistance
(ideally 0.5 to 1 Ohm).
The graph on the right shows the
recommended CSA for different
lengths of loop cable. Simply
work out the length of the loop
required and choose a cable size
that falls into the non-shaded
area of the graph.
50
100
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 7
In addition to the amplifier’s two XLR inputs (MIC. and MIC./LINE), up to 10 additional
microphone or line level inputs (any mix) can be daisychained to the amplifier’s ‘OUTREACH’
connector via a range of specially designed wall, ceiling or desk mountable single gang plates.
Several different Outreach plates are available covering the most common variants of audio
connecto
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 8
Induction loop amplifier (1)
Designed to be free-standing or, if required, wall or rack
mounted using our optional PDA/WM or PDA/RM kits.
Loop cable (4)
Run the loop cable (see page 6 for recommended
cable types) around the perimeter of the room at
floor or ceiling height. Note that ceiling loops will
not be practical in all applications, i.e. churches with
high roofs.
If install
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 9
AML lectern microphone (12) connected to the
amplifier via an APJ Outreach plate (13)
Hanging ambient microphone (14) connected to the
amplifier via an APXM Outreach plate (15)
Positioned over the congregation to help convey ambient noise
and pick up the singing of hymns, etc.
Outreach network (11)
Daisychain standard two pair audio
cable such as Belden 8723 to all
Outreach plates
PDA Range PDA200/2 PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 10
Safety precautions
Ensure the amplifier IS NOT located in areas with high ambient temperatures or high levels
of humidity, moisture or dust. It SHOULD NOT be exposed to direct sunlight or water nor be
placed next to vibrating or heat-generating equipment.
The amplifier should never be covered with any object that could impede the flow of air to
its cooling fan and we recommend t
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 11
SW1
1
2
3
4
Connecting and testing the system
Install the loop - see Planning the System, pages 6 to 9, for example layouts and
positioning advice.
Before connecting the loop to the amplifier, use a multimeter to check the loop is not
shorted to ground at any point. It WILL almost certainly damage the amplifier if it is.
Connect the loop to the amplifier’s heavy duty binding p
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 12
8
9
7
10
The loop strength meter’s red peak indicator (the fifth LED on the gauge)
should only illuminate with peaks in the input signal - if it is lit too
frequently, the audio sound quality will be distorted and the amplifier may
overheat. If this is the case, try adjusting the layout of the loop and/or consider
purchasing a more powerful PDA range amplifier.
If it is impossi
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 13
For compliance with BS7594 (the code of practice for audio-frequency induction loop
systems), we recommend you also check the system using a pink noise generator and
magnetic field strength meter.
BS7594 recommends that the magnetic field strength of an AFILS over a covered area
should be 100mA RMS average peaking to 400mA per metre. The most efficient way of
ensuring this requi
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 14
PDA Pro-Range technical specifications
POWER
230-240 V a.c. mains (PDA200/2 <150 VA; PDA500/2 <225 VA; PDA1000/2 <300 VA)
(IEC 320 fused mains lead supplied)
INPUTS
Line (3 pin XLR type)
Input impedance: 6k8 + or – input to ground.
Sensitivity: 200mV – 2.5V RMS balanced or unbalanced.
Microphones (3 pin XLR type)
Input impedance: 6k8 + or – input to ground.
Sensitivity: 1
PDA Range PDA200/2 PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 15
Compressor: Gives dynamically variable compression ratio from 1:1 (no compression) to 17:1 when both
compression LEDs are lit. In normal use, with the first compression LED lit for part of the time, the
compressor has a “soft knee” characteristic and provides a small degree of compression for signals which
only just light the first LED but a large degree of compression for lo
PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 16
© 2004. Errors and omissions excepted. The manufacturer of this equipment operates a policy of continuous
improvement and reserves the right to alter product specifications at its discretion and without prior notice.
PDA PRO-RANGE AMPLIFIERS AND MOUNTING KITS
PDA200/2
200m2 free-standing professional induction loop amplifier
PDA500/2
500m2 free-standing professional induction l