PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 1

PDA200/2, PDA500/2, PDA1000/2 INSTALLATION INSTRUCTIONS This equipment must be installed by a suitably skilled and technically competent person. Please read these instructions carefully before installation. Important notes .......................................................................................... 2 What is an audio frequency induction loop system? ................

PDA Range PDA200/2 PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 2

Important notes These instructions are general and cannot be considered to cover every aspect of audio-frequency induction loop system design and installation. We recommend you read BS7594 (The Code of Practice for Audio-Frequency Induction Loop Systems) and EN60118-4 (Magnetic field strength in audio frequency induction loop systems for hearing aid purposes), copies of which are

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 3

An audio-frequency induction loop system (AFILS) allows hearing impaired people to hear more clearly. Most hearing aids have a ‘T’ or ‘MT’ switch which allows them to pick up the electromagnetic field generated by an induction loop system. The hearing aid converts this signal into a sound suited to its user’s specific hearing requirements. Any hearing impaired person pos

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 4

INPUT MODE SELECT SWITCH Allows the MIC./LINE input to be configured for Mic or Line operation and for optional 11V phantom power to be switched to the inputs. SW1 1 2 3 4 Familiarisation with your Pro-Range induction loop amplifier MIC. INPUT Accepts standard three-pin male XLR type connectors. Optional 11V phantom power is available via input mode select switch 1. MIC./LINE INPU

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 5

COMPRESSION INDICATORS Give a visual indication of the amplifier’s compressor activity. Installers should refer to these indicators when using the amplifier’s input signal level controls. For best results, we recommend you set the inputs so that the LOW compression indicator is lit most of the time and the HIGH compressor indicator illuminates only with peaks in the input sign

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 6

Loop cable selection Almost any single core tri-rated cable can be used for the induction loop provided it is of the appropriate DC resistance (ideally 0.5 to 1 Ohm). The graph on the right shows the recommended CSA for different lengths of loop cable. Simply work out the length of the loop required and choose a cable size that falls into the non-shaded area of the graph. 50 100

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 7

In addition to the amplifier’s two XLR inputs (MIC. and MIC./LINE), up to 10 additional microphone or line level inputs (any mix) can be daisychained to the amplifier’s ‘OUTREACH’ connector via a range of specially designed wall, ceiling or desk mountable single gang plates. Several different Outreach plates are available covering the most common variants of audio connecto

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 8

Induction loop amplifier (1) Designed to be free-standing or, if required, wall or rack mounted using our optional PDA/WM or PDA/RM kits. Loop cable (4) Run the loop cable (see page 6 for recommended cable types) around the perimeter of the room at floor or ceiling height. Note that ceiling loops will not be practical in all applications, i.e. churches with high roofs. If install

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 9

AML lectern microphone (12) connected to the amplifier via an APJ Outreach plate (13) Hanging ambient microphone (14) connected to the amplifier via an APXM Outreach plate (15) Positioned over the congregation to help convey ambient noise and pick up the singing of hymns, etc. Outreach network (11) Daisychain standard two pair audio cable such as Belden 8723 to all Outreach plates

PDA Range PDA200/2 PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 10

Safety precautions Ensure the amplifier IS NOT located in areas with high ambient temperatures or high levels of humidity, moisture or dust. It SHOULD NOT be exposed to direct sunlight or water nor be placed next to vibrating or heat-generating equipment. The amplifier should never be covered with any object that could impede the flow of air to its cooling fan and we recommend t

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 11

SW1 1 2 3 4 Connecting and testing the system Install the loop - see Planning the System, pages 6 to 9, for example layouts and positioning advice. Before connecting the loop to the amplifier, use a multimeter to check the loop is not shorted to ground at any point. It WILL almost certainly damage the amplifier if it is. Connect the loop to the amplifier’s heavy duty binding p

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 12

8 9 7 10 The loop strength meter’s red peak indicator (the fifth LED on the gauge) should only illuminate with peaks in the input signal - if it is lit too frequently, the audio sound quality will be distorted and the amplifier may overheat. If this is the case, try adjusting the layout of the loop and/or consider purchasing a more powerful PDA range amplifier. If it is impossi

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 13

For compliance with BS7594 (the code of practice for audio-frequency induction loop systems), we recommend you also check the system using a pink noise generator and magnetic field strength meter. BS7594 recommends that the magnetic field strength of an AFILS over a covered area should be 100mA RMS average peaking to 400mA per metre. The most efficient way of ensuring this requi

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 14

PDA Pro-Range technical specifications POWER 230-240 V a.c. mains (PDA200/2 <150 VA; PDA500/2 <225 VA; PDA1000/2 <300 VA) (IEC 320 fused mains lead supplied) INPUTS Line (3 pin XLR type) Input impedance: 6k8 + or – input to ground. Sensitivity: 200mV – 2.5V RMS balanced or unbalanced. Microphones (3 pin XLR type) Input impedance: 6k8 + or – input to ground. Sensitivity: 1

PDA Range PDA200/2 PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 15

Compressor: Gives dynamically variable compression ratio from 1:1 (no compression) to 17:1 when both compression LEDs are lit. In normal use, with the first compression LED lit for part of the time, the compressor has a “soft knee” characteristic and provides a small degree of compression for signals which only just light the first LED but a large degree of compression for lo

PDA Pro-Range Instructions • Approved Doc. No. DCP0003168 Rev 1 • Page 16

© 2004. Errors and omissions excepted. The manufacturer of this equipment operates a policy of continuous improvement and reserves the right to alter product specifications at its discretion and without prior notice. PDA PRO-RANGE AMPLIFIERS AND MOUNTING KITS PDA200/2 200m2 free-standing professional induction loop amplifier PDA500/2 500m2 free-standing professional induction l

PDA Range Amplifier Owners Instructions: