PDA Range 103 Installation Instructions Manual
Text of PDA Range 103 Installation Instructions Manual
INDUCTION LOOP AMPLIFIER
The PDA103 is a true current mode, audio-frequency induction loop amplifier. It may be
surface-mounted and is designed to cover ticket counters up to 1.2m2 (PDA103C kit version),
or rooms up to 50m2 (PDA103R/L/S kit versions).
Safety guidelines, important notes and product safety notes........................................... 2
PDA103 kit contents ............................................................
Avoid placing the PDA103 amplifier in areas:
• with poor ventilation
• exposed to direct sunlight
• with high ambient temperatures
• adjacent to heat generating equipment
• with high humidity or dust levels
• susceptible to severe vibration
DO NOT dismantle or attempt to modify the amplifier. No user-serviceable fuses or parts are
included inside the amplifier. For repair, contact your supplier.
WARNING: The surface of this un
IMPORTANT: DO NOT power up the system before completing Step 7 below.
The amplifier MUST NOT be operated without a loop connected to it.
Install the loop cable.
BEFORE connecting the loop to the amplifier, use a multimeter to check the loop is not
shorted to ground at any point. It WILL damage the amplifier if it is.
Connect the loop cable (supplied) to the amplifier.
Remove a
The amplifier mixes and amplifies the microphone, line, digital and outreach input signals
and feeds them through its sophisticated automatic gain control (AGC) circuitry before
outputting them to the induction loop.
OVERVIEW OF THE PDA103 INDUCTION LOOP AMPLIFIER
103
Loop
DCin
+
-
14V to 20V
Mic
Line
Digital
Outreach
Power On
Loop Fault
Peak
Limit
Level
Metal
Compensation
4 of 12
3*
9
10
11
12
4
2
1
8
7
5
6
Connectors, controls and indic
8 of 12
103
Loop
DCin
+
-
14V to 20V
Mic
Line
Digital
Outreach
Power On
Loop Fault
Peak
Limit
Level
Metal
Compensation
TYPICAL PDA103S 50m2DOMESTIC TV/MUSIC LOUNGE LOOP SYSTEM
4
3
1
PDA103S Kit Components
1
AFILS sticker:
Position the sticker where it can be clearly seen by hearing
aid users.
2
APL dual phono line
level ‘outreach’ plate
c/w APS SCART lead &
Belden connection cable:
Surface-mount the APL plate onto a standard 25mm UK
back box - a 6m len
If multiple counter loops are
required in close proximity, it
is possible that the ‘field’
generated by one system may
be picked up by a person who
is standing at the next. Adjust
the field strength and loop
shape to avoid this.
TYPICAL PDA103C 1.2m2 COUNTER LOOP SYSTEM
MULTIPLE
COUNTER LOOPS
PDA103C Kit Components
1
AFILS sticker:
Position the sticker where it can be clearly seen by hearing aid users.
2
AMT tie/desk
microphone
c/w 1.5m lead:
Position