PDA200E Induction Loop System
Installation Guide
Key Features
The PDA200E is a cost-effective induction loop amplifier that is designed to drive a perimeter
loop of up to 200 square metres. It provides the following key features:
•
Fully compliant as a perimeter loop system as described in BS 7594, clause 10 A3 and BS EN
60118-4 when correctly installed
•
Up to 200 square metres (metal free) coverage - ideal for most ‘free space’ applications
•
T
PDA200E Example Schematic
This schematic shows an example system which utilises a desk mounted microphone (AMT) directly
wired into the PDA200E and two Outreach plate microphones (APM).
Approved Document No. DCP0002129 Rev 7
2 of 12
Mains wiring
Neutral (N)
230 Vac (L)
Earth
N
L
FUSE
Mains connection
and fuse information
is detailed on page 4
P2
P1
P3
RV1
RV3
RV5
RV2
RV4
VR1
DO NOT ADJUST
LINE 1
LINE 2
MIC
MET COMP
DRIVE
Loop cable (1 mm2 single core)
3.
Approved Document No. DCP0002129 Rev 7
3 of 12
Important Information
•
This equipment is a piece of Class 1 equipment and MUST BE EARTHED.
•
This installation guide MUST NOT be left accessible to the user.
•
ALWAYS isolate the amplifier’s Mains supply before making connections to its PCB.
Equipment guarantee
This equipment is not guaranteed unless the system is installed and commissioned in
accordance with the relevant regional or national standard
Approved Document No. DCP0002129 Rev 7 9 of 12
Second Fix
Internal controls
Five internal pot controls (shown in diagram below) are located on the PDA200E’s PCB, which is
mounted internally on the unit’s lid. The fully anti-clockwise position is the control’s minimum
setting (note that factory default setting is mid-position).
The LINE 1 and LINE 2 Level controls are used to set the signal levels of the line level inputs into
the amplifier. Apply an
Overspill and more complex installations
The magnetic field is not confined to the area within the loop and the signal may be heard in
adjacent areas such as a corridors and up to three times the width of the loop away. If this is a
problem there are special designs of loop that can reduce the overspill field.
The AFILS British Standard (BS 7594) suggests several technically complex solutions that are
reasonably effective but are not commonly employed due
Approved Document No. DCP0002129 Rev 7 7 of 12
Installing the Loop Cable
The loop cable should be laid in a single turn and wired into the PDA200E’s termination block
labelled LOOP- and LOOP+, as shown in the diagram on page 2 of this guide.
In the vast majority of cases loop cables are normally mounted horizontally around the perimeter
of the room to be covered, either at ceiling or floor height. They may also be installed under
carpet by using flat loo