T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200

Subject to change without notice Product described VMS6200 Document No. 8025140 Manufacturer SICK AG Erwin-Sick-Str. 1 · 79183 Waldkirch · Germany www.sick.com Legal notes This work is protected by copyright. The associated rights are reserved by SICK AG. Reproduction of this document or parts of this document is only permi

Subject to change without notice

T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 Contents 1 About this document ........................................................................................................ 5 1.1 Limitation of liability ............................................................................................. 5 1.2 Purpose of this docu
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 Subject to change without notice 5.4 Connecting the volume measurement devices ................................................36 5.5 Connection for the photoelectric retro-reflective sensor .................................37 5.6 Connecting the incremental encoder ......................................................

SICK VMS6200 ABOUT THIS DOCUMENT 1

5 80251340/2020-02-03|SICK Subject to change without notice T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 1 About this document This document regarding the VMS6200 volume measurement system: • contains information that is required during the life cycle of the system. • must be made available to all those who work with the system. • should be read through carefully, and

1 ABOUT THIS DOCUMENT

6 8025140/2020-02-03|SICK T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 Subject to change without notice 1.4 Further information Special local conditions The local laws, regulations, technical rules and internal company operating instructions at the usage site must be observed. Storage of documents This document and other relevant technical documentation/information: • Mu

SAFETY INFORMATION 2

7 80251340/2020-02-03|SICK Subject to change without notice T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 2 Safety information 2.1 Intended use The VMS6200 track and trace system is used to solve demanding applications in the area of object measurement and position determination. Not only large objects, but also black, foiled or highly reflective objects can be dynamically an

2 SAFETY INFORMATION

8 8025140/2020-02-03|SICK T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 Subject to change without notice 2.3 Requirements for the qualification of personnel Only qualified persons with the relevant technical expertise are permitted to work on the system. • Qualified persons have the specialist training, skills, and experience, as well as knowledge of the relevant regulatio
SAFETY INFORMATION 2 9 80251340/2020-02-03|SICK Subject to change without notice T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 2.7 Safety conventions The warnings used in this manual have the following meanings: DANGER Identifies an imminent danger, which will lead to death or serious injuries if not prevented. WARNING Identifies a situation presenting danger, which will lead to death or serious
2 SAFETY INFORMATION 10 8025140/2020-02-03|SICK T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 Subject to change without notice 2.8 Warning symbols on the system components Warning labels must not be removed or covered up. If labels are missing, these must be affixed. Damaged labels must be replaced. Symbol Meaning Hazardous point warning Hazardous electrical voltage warning Laser beam warning Su
SAFETY INFORMATION 2 11 80251340/2020-02-03|SICK Subject to change without notice T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 2.10 Safety notes DANGER! HAZARDOUS ELECTRICAL VOLTAGE Touching live devices can lead to death, burns or electrical shock. ▸ Electrical work may only be performed on the system by qualified specialist personnel. ▸ Before working on electrical components, observe the

SICK VMS6200 3 SYSTEM DESCRIPTION

12 8025140/2020-02-03|SICK T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 Subject to change without notice 3 System description 3.1 Scope of delivery NOTE! ▸ After delivery, inspect the system for transport damage and report any such damage immediately. ▸ Check that the delivery includes all components listed on the delivery note. System components • Cabinet with MSC800

SYSTEM DESCRIPTION 3

13 80251340/2020-02-03|SICK Subject to change without notice T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 3.2 System components Fig. 1: Components of the VMS6200 Legend 1 2D LiDAR sensor 2 Photoelectric retro-reflective sensor (optional) 3 Incremental encoder (optional) 4 Cabinet with MSC800, VMC800, power supply unit, and Ethernet switch • The system components are mounte
3 SYSTEM DESCRIPTION 14 8025140/2020-02-03|SICK T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 Subject to change without notice 3.2.1 LMS500 2D LiDAR sensors Fig. 2: LMS500 with adapter plate and mounting plate Legend 1 Mounting plate for mounting on a frame 2 Adapter plate with adjustment unit for attaching the LMS500 3 System plug with parameter set 4 Status indicators 5 Beam exit • Two LMS50
SYSTEM DESCRIPTION 3 15 80251340/2020-02-03|SICK Subject to change without notice T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 3.2.2 Trigger photoelectric sensor Fig.3: Photoelectric retro-reflective sensor with reflector (e.g., WL18-3) Legend 1 Photoelectric retro-reflective sensor (e.g., WL18-3) 2 Reflector • Photoelectric retro-reflective sensor trigger available as an option. • The emitt
3 SYSTEM DESCRIPTION 16 8025140/2020-02-03|SICK T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 Subject to change without notice 3.2.3 Incremental encoder Fig. 4: DFV60 incremental encoder Legend 1 Measuring wheel 2 Spring-loaded mounting arm • Optionally available measuring wheel system mounted below the conveying equipment. • Large spring travel and pivot range of the spring arm compensates
SYSTEM DESCRIPTION 3 17 80251340/2020-02-03|SICK Subject to change without notice T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 3.2.4 Cabinet Fig. 5: Components in the cabinet Legend 1 Air inlet for cooling (with filter mat and cooler) 2 Ethernet switch for connecting the system components 3 VMC800 volume measurement controller 4 Air outlet for cooling (with filter mat) 5 Terminals (24 V DC) and
3 SYSTEM DESCRIPTION 18 8025140/2020-02-03|SICK T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 Subject to change without notice 3.3 Operating principle 3.3.1 Automated operating mode The VMS6200 runs fully automatically after startup. No manual intervention by the operator is required. Fig. 6: Transport conditions – singulated measurement • The VMS6200 measurement system is capable of identif
SYSTEM DESCRIPTION 3 19 80251340/2020-02-03|SICK Subject to change without notice T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 Fig. 8: Minimum separation calculation for palletized freight with straps/wrapping • Similarly, pallet wrapping or straps need to be taken into consideration when calculating the separation for objects on pallets. Fig. 9: No touching, no side-by-side • The objects mu