SICK VMS6200 Operating Instructions Manual
Text of SICK VMS6200 Operating Instructions Manual
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
Subject to change without notice
Product described
VMS6200
Document No.
8025140
Manufacturer
SICK AG
Erwin-Sick-Str. 1 · 79183 Waldkirch · Germany
www.sick.com
Legal notes
This work is protected by copyright. The associated rights are reserved by SICK AG.
Reproduction of this document or parts of this document is only permi
Subject to change without notice
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
Contents
1
About this document ........................................................................................................ 5
1.1
Limitation of liability ............................................................................................. 5
1.2
Purpose of this docu
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200 Subject to change without notice
5.4
Connecting the volume measurement devices ................................................36
5.5
Connection for the photoelectric retro-reflective sensor .................................37
5.6
Connecting the incremental encoder ......................................................
SICK VMS6200 ABOUT THIS DOCUMENT 1
5
80251340/2020-02-03|SICK
Subject to change without notice
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
1
About this document
This document regarding the VMS6200 volume measurement system:
• contains information that is required during the life cycle of the system.
• must be made available to all those who work with the system.
• should be read through carefully, and
1 ABOUT THIS DOCUMENT
6
8025140/2020-02-03|SICK
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
Subject to change without notice
1.4
Further information
Special local conditions
The local laws, regulations, technical rules and internal company operating instructions at
the usage site must be observed.
Storage of documents
This document and other relevant technical documentation/information:
• Mu
SAFETY INFORMATION 2
7
80251340/2020-02-03|SICK
Subject to change without notice
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
2
Safety information
2.1
Intended use
The VMS6200 track and trace system is used to solve demanding applications in the area
of object measurement and position determination.
Not only large objects, but also black, foiled or highly reflective objects can be dynamically
an
2 SAFETY INFORMATION
8
8025140/2020-02-03|SICK
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
Subject to change without notice
2.3
Requirements for the qualification of personnel
Only qualified persons with the relevant technical expertise are permitted to work on the
system.
• Qualified persons have the specialist training, skills, and experience, as well as
knowledge of the relevant regulatio
SAFETY INFORMATION 2 9
80251340/2020-02-03|SICK
Subject to change without notice
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
2.7
Safety conventions
The warnings used in this manual have the following meanings:
DANGER
Identifies an imminent danger, which will lead to death or serious injuries if not
prevented.
WARNING
Identifies a situation presenting danger, which will lead to death or serious
2 SAFETY INFORMATION 10
8025140/2020-02-03|SICK
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
Subject to change without notice
2.8
Warning symbols on the system components
Warning labels must not be removed or covered up. If labels are missing, these must be
affixed. Damaged labels must be replaced.
Symbol
Meaning
Hazardous point warning
Hazardous electrical voltage warning
Laser beam warning
Su
SAFETY INFORMATION 2 11
80251340/2020-02-03|SICK
Subject to change without notice
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
2.10
Safety notes
DANGER!
HAZARDOUS ELECTRICAL VOLTAGE
Touching live devices can lead to death, burns or electrical shock.
▸ Electrical work may only be performed on the system by qualified specialist
personnel.
▸ Before working on electrical components, observe the
SICK VMS6200 3 SYSTEM DESCRIPTION
12
8025140/2020-02-03|SICK
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
Subject to change without notice
3
System description
3.1
Scope of delivery
NOTE!
▸ After delivery, inspect the system for transport damage and report any such damage
immediately.
▸ Check that the delivery includes all components listed on the delivery note.
System components
• Cabinet with MSC800
SYSTEM DESCRIPTION 3
13
80251340/2020-02-03|SICK
Subject to change without notice
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
3.2
System components
Fig. 1:
Components of the VMS6200
Legend
1
2D LiDAR sensor
2
Photoelectric retro-reflective sensor (optional)
3
Incremental encoder (optional)
4
Cabinet with MSC800, VMC800, power supply unit, and Ethernet switch
• The system components are mounte
3 SYSTEM DESCRIPTION 14
8025140/2020-02-03|SICK
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
Subject to change without notice
3.2.1
LMS500 2D LiDAR sensors
Fig. 2:
LMS500 with adapter plate and mounting plate
Legend
1
Mounting plate for mounting on a frame
2
Adapter plate with adjustment unit for attaching the LMS500
3
System plug with parameter set
4
Status indicators
5
Beam exit
• Two LMS50
SYSTEM DESCRIPTION 3 15
80251340/2020-02-03|SICK
Subject to change without notice
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
3.2.2
Trigger photoelectric sensor
Fig.3:
Photoelectric retro-reflective sensor with reflector (e.g., WL18-3)
Legend
1
Photoelectric retro-reflective sensor (e.g., WL18-3)
2
Reflector
• Photoelectric retro-reflective sensor trigger available as an option.
• The emitt
3 SYSTEM DESCRIPTION 16
8025140/2020-02-03|SICK
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
Subject to change without notice
3.2.3
Incremental encoder
Fig. 4:
DFV60 incremental encoder
Legend
1
Measuring wheel
2
Spring-loaded mounting arm
• Optionally available measuring wheel system mounted below the conveying equipment.
• Large spring travel and pivot range of the spring arm compensates
SYSTEM DESCRIPTION 3 17
80251340/2020-02-03|SICK
Subject to change without notice
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
3.2.4
Cabinet
Fig. 5:
Components in the cabinet
Legend
1
Air inlet for cooling (with filter mat and cooler)
2
Ethernet switch for connecting the system components
3
VMC800 volume measurement controller
4
Air outlet for cooling (with filter mat)
5
Terminals (24 V DC) and
3 SYSTEM DESCRIPTION 18
8025140/2020-02-03|SICK
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
Subject to change without notice
3.3
Operating principle
3.3.1
Automated operating mode
The VMS6200 runs fully automatically after startup. No manual intervention by the
operator is required.
Fig. 6:
Transport conditions – singulated measurement
• The VMS6200 measurement system is capable of identif
SYSTEM DESCRIPTION 3 19
80251340/2020-02-03|SICK
Subject to change without notice
T R A N S L A T I O N O F T H E O R I G I N A L O P E R A T I N G I N S T R U C T I O N S | VMS6200
Fig. 8:
Minimum separation calculation for palletized freight with straps/wrapping
• Similarly, pallet wrapping or straps need to be taken into consideration when
calculating the separation for objects on pallets.
Fig. 9:
No touching, no side-by-side
• The objects mu