SINGLE CHANNEL LOOP DETECTOR

OPERATING INSTRUCTIONS I General The Model H2 is a single channel detector with a solid state Detect Output and a solid state Fail Output. Please verify source voltage before applying power. The Model H2 will operate on voltages between 8 and 30 VDC with a maximum current requirement of 45 mA. II Indicators and Controls i Power

iii DIP Switches

Switch OFF ON Factory Default 1 Frequency (See table in Frequency section) OFF 2 ON 3 Fail-Safe Fail-Secure OFF 4 No Boost Sensitivity Boost OFF 5 Detect Output Delay (See table in Output Delay section) OFF 6 OFF 7 Detect Output Extension (See table in Output Extension section) OFF 8 OFF Frequency (DIP Switches 1 and 2) When loops are loc

Detect Output Delay (DIP Switches 5 and 6)

An Output Delay time of zero, two, five, or ten seconds can be programmed using DIP switches 5 and 6. Output Delay time is the time before the Detect Output activates following vehicle detection. If the Output Delay feature is programmed to a value other than zero the Detect Output is "ON" only if a vehicle is

Model H2 Operating Instructions

P/N 889-0805-00 4 IV Failed Loop Diagnostics The Fail LED (red) provides loop failure information. The Fail LED is "OFF" when the loop inductance value is within tolerance, and no past out of tolerance conditions have existed. The Fail LED flashes at a one Hertz rate (50% duty cycle) when the current loop inductance value is