Rae P-1400 Operation Manual
Text of the manual
This manual contains technical information for the
P-1400 Loop Detector
pn 889-1600-04 Revision: April 2020
P-1400
Loop Detector
Firmware Version 4.02
Operations Manual
Four Channel Menu Drive Programmable Inductive Loop Vehicle
Detector Designed for Railroad Applications
Four Loop Inputs, Two Vital Outputs, and One Vital Input
Built-in Loop Analyzer for Eac
THE FOLLOWING PRODUCT WAS DESIGNED, INSPECTED, TESTED AND
MANUFACTURED IN THE USA BY EBERLE DESIGN, INC. IN PHOENIX, ARIZONA.
INFORMATION CONTAINED HEREIN IS PROPRIETARY TECHNICAL INFORMATION OF
EBERLE DESIGN, INC. PUBLICATION, REPRODUCTION OR USE IN WHOLE OR PART IS
NOT PERMITTED EXCEPT UNDER TERMS AGREED UPON IN WRITING. ALL
REGISTERED TRADEMARKS OF EBERLE
Model P-1400 Operations Manual
Table of Contents
Section 1 General Description ................................................................................................................................ 1
Section 2 General Characteristics ....................................................................................................................
Model P-1400 Operations Manual Rev Apr 2020 Page 1 of 33
Section 1 General Description
This product manual was written for people installing, operating, and maintaining the Reno A&E Model P-1400
inductive loop vehicle detector. The Model P-1400 is a four-channel inductive loop vehicle detector designed as a
direct, drop-in replace
Model P-1400 Operations Manual Rev Apr 2020 Page 2 of 33
Section 2 General Characteristics
2.1 LOOP FREQUENCY
There are eight selectable loop frequency settings (normally in the range of 20 to 100 kilohertz) per loop input.
The actual loop operating frequency is a function of the loop / lead-in network and the components of the loo