Ascon tecnologic e33B Operating Instructions Manual

Brand: Ascon tecnologic
Category: Temperature Controller
Model: e33B (Operating Instructions Manual)
File Type: PDF
File Size: —
Pages: 19
Text of Ascon tecnologic e33B Operating Instructions Manual

Ascon Tecnologic - e33B - OPERATING INSTRUCTIONS - PAG. 1

e33B DIGITAL ELECTRONIC TEMPERATURE CONTROLLER WITH DEFROSTING FUNCTION OPERATING INSTRUCTIONS Vr 02 (ENG) - 18/10 - cod.: ISTR-Me33BENG02 ASCON TECNOLOGIC S.r.l. Viale Indipendenza 56, 27029 - VIGEVANO (PV) ITALY Tel.: +39 0381 69871 - Fax: +39 0381 698730 http:\\www.ascontecnologic.com [email protected] PREFACE D D This manual contains the information necessary for the product to be instal

Ascon tecnologic e33B Ascon Tecnologic - e33B - OPERATING INSTRUCTIONS - PAG. 2

temperature control device, the defroster, the evaporator fans and a configurable auxiliary device (Light, Alarm, etc.). The 3 inputs for temperature probes can be used for the cell temperature control, to measure the evaporator tem- perature and/or other auxiliary temperatures (e.g. products temperature, condenser temperature, etc.). The digital input, alternative to the Pr3 probe, can be config- u

Ascon tecnologic e33B Ascon Tecnologic - e33B - OPERATING INSTRUCTIONS - PAG. 3

2.2 Standard mode parameters programming To access the instrument function parameters when pass- word protection is disabled, press the keys / and / at the same time and keep them pressed for about 5 s, after which the display shows the code that identifies the first pro- grammable parameter. Press the / keys to display the desired parameter, then, pressing the / key, the display shows the param

Ascon Tecnologic - e33B - OPERATING INSTRUCTIONS - PAG. 4

When the keyboard is locked, if any of the key is pressed, the display showss Ln to indicate that the lock is active. To unlock the keyboard it is enough to contemporaneously press / + / keys and keep them pushed for 5 s, after which the label LF appears on the display and all the key functions will be available again. 2.7 Variables display The display normally shows the variable set with paramete

Ascon tecnologic e33B Ascon Tecnologic - e33B - OPERATING INSTRUCTIONS - PAG. 5

4.3 Electrical connections Carry out the electrical wiring by connecting only one wire to each terminal, according to the following diagram, checking that the power supply is the same as that indicated on the instrument and that the load current absorption is no higher than the maximum electricity current permitted. As the instrument is built-in equipment with permanent con- nection inside housing,

Ascon Tecnologic - e33B - OPERATING INSTRUCTIONS - PAG. 6

If iEt = oF the selection of Eco/Normal modes via the digital input is disabled. If itt = oF the time-out switching from Eco to Normal mode is disabled. Temp. SPE SP rd rEd iEt (1) iEt time Normal Normal eco iTt (2) Pr1 Switching to Economic mode is indicated by the label Eco. In addition, the selection of the Eco mode is always com- bined with the function of turning OFF the output configured as L1

Ascon Tecnologic - e33B - OPERATING INSTRUCTIONS - PAG. 7

5.4 Digital input configuration The digital input function (available on terminal 12 or instead of Pr3 input if ip3 = dg) is defined using the iFi parameter and the action is delayed for the time programmed with pa- rameter iti. The iFi parameter can be configured for the following functions: 0 Digital input not active; 1 Cell door opening with NO contact: at input closure (and after the iti) the i

Ascon tecnologic e33B Ascon Tecnologic - e33B - OPERATING INSTRUCTIONS - PAG. 8

5.6 Temperature control The instrument controls the temperature with an ON/OFF action and operates on the outputs configured as ot and HE depending on the PR1 probe measuring, the acive Set Point/s SP1 (or SP2, SP3, SPE and SPH), the Hysteresis rd (or rEd and/or rHd) and the function mode set with rHC. Using rHC can be set the following functioning modes: C Cooling; H Heating. SP Temp. rd time off o

Ascon Tecnologic - e33B - OPERATING INSTRUCTIONS - PAG. 9

eter Pod. During the power ON delay phase, the display shows the indication od alternated with the normal visualization. All these functions are disabled if the relative parameters are set to OFF (oF). 5.8 Defrost control The defrost control acts on the outputs configured as ot and dF. The type of defrost is set by the parameter ddt: EL With electrical heating (or By stopping compres- sor): while de

Ascon tecnologic Temperature Controller Owners Instructions: