READ THIS FIRST
CHECK OPERATION OF SYSTEM
TEST BUTTONS OPERATE ON ALL ALARMS.
ALL INTERCONNECTED ALARMS OPERATE
WHEN EACH TEST BUTTON IS PRESSED FOR
10 SECONDS.
IF THE UNIT BEEPS EVERY 40 SECONDS FOR
OVER 20 MINUTES THE BATTERY IS PROBABLY
DEPLETED. REMOVE UNIT FROM CEILING (SEE
FIG 1) AND REPLACE BATTERY.
DO NOT ATTEMPT TO OPEN THE ALARM AS IT
IS PERMANENTLY SEALED FOR SAFETY.
IF A NUISANCE ALARM OCCURS PRESS THE
TEST/HUSH BUTTON TO SILENCE THE ALARM
FOR
Sufficient smoke must enter the Smoke Alarm before it will
respond. The Smoke Alarm needs to be within 7.5 metres
(25 ft) of the fire to respond quickly. It also needs to be in a
position where its alarm can be heard throughout your
home, so it can wake the occupants in time for all to
escape. A single Smoke Alarm will give some protection if it
is properly installed, but most homes will require two or
more to ensure that a rel
Ei Electronics Ei 181 Ionisation Figure 2 illustrates where Smoke Alarms and Heat Alarms
should be located in a typical two storey house. Note the
spacings in “Recommended Protection” which help ensure
the early detection of fire and that the warning will be heard.
Locate Heat Alarms in rooms adjoining or on escape routes
- kitchens, garages, boiler houses etc. where Smoke
Alarms are unsuitable. Install within 5.3m (17 feet) of
potential sources of fire.
Single S
Ei Electronics Ei 181 Ionisation In houses with more than one sleeping area, Smoke Alarms
should be placed between each sleeping area and the living
area.
Multi Storey Dwellings
If the dwelling has more than one storey it must have an
interconnected alarm on each level for minimum protection.
Maximum Protection
For maximum protection you should put individual Smoke
Alarms in all the rooms where fire is most likely to break out
(apart from the locations to avoid, mentioned below).
Ensure t
Ei Electronics Ei 181 Ionisation LOCATIONS TO AVOID
Don’t place Smoke Alarms in any of the following areas:
• Bathrooms, kitchens, shower rooms, garages or other
rooms where the smoke alarm may be triggered by
steam, condensation, normal smoke or fumes. Keep at
least 6 metres (20 feet) away from sources of smoke.
Don’t place Heat Alarms in any of the following areas:
• Bathrooms, shower rooms or other room where the unit
may be triggered by steam or condensation.
Don’t place Smo
POSITIONING SMOKE/HEAT ALARMS
The locations must comply with applicable building
regulations.
Hot smoke rises and spreads out, so a central ceiling
position is the preferred location. The air is “dead” and does
not move in corners, therefore Smoke & Heat Alarms must
be mounted away from corners. Place the unit at least
300mm (12 inches) from any light fitting or decorative object
which might obstruct smoke / heat entering the Alarm.
Keep at least 300m
Systems using more than 3 or 4 alarms must be very
carefully planned to ensure nuisance alarms are not
excessive, e.g. from cooking or weekly testing.
Smoke Alarm Locator Switch (Ei159) should be incorporated
into the system and be readily accessible to all occupants
so that the source of an alarm can be quickly identified. (see
Accessory section).
All Alarms must be cleaned and maintained regularly.
A competent person must be on call to quickly remove any
cover it completely, particularly around the edges, with
a dust cover (eg. with the elasticated cover supplied or
a plastic bag), until all cleaning is finished.
Warning: Wiring should only be installed by an Electrician
in accordance with current IEE wiring regulations for
electrical installation. The installation must also be in
accordance with the control panel instructions and the
instructions in this leaflet.
Warning: The mains circuit used to power t
Ei Electronics Ei 181 Ionisation Press the test/hush button for 10 seconds. The horn should
sound.
7. Connect the panel power to the alarm circuit. The green
light on the mounting plate should turn on.
Check the operation of the Alarm as outlined in the next
section.
CHECKING AND MOUNTING YOUR
ALARMS
INSPECTION & TESTING PROCEDURE
After installation, after re-occupation following a holiday,
and weekly, check all your Alarms as follows:
Check the green light is illuminated on the mounting
This can set fire to the Alarm and damage the house.
We do not recommend testing with smoke or heat as the
results can be misleading unless special apparatus is used.
Check for any sign of contamination such as cobwebs or
dust and clean the alarm as described below if necessary.
Interconnected alarms
Test the first unit by pressing the button. All the detectors
should alarm within about 5 seconds of the first horn
sounding and the red light on the first un
We recommend that the functioning of the battery back-up
is checked after installation and then at least yearly as
follows:-
Turn off (or disconnect) the power at the panel (green light
on mounting plate should be off) press the test button and
ensure the horn sounds loudly for 10 seconds. (This checks
the battery back-up models Ei181, Ei184 and Ei186 only).
Note: A good battery can supply the unit for over a year in
standby (or 5 hours in
Ei Electronics Smoke Alarm Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
Ei160 |
Ei Electronics Ei160 Guide (Instruction leaflet), @21B8N2 |
4 | 0.15 Mb | 1054 | 201 | 26-05-2026 |
EiA207 Series |
#H316J6: EiA207 Series Smoke Alarm Instructions manual |
12 | 621 | 112 | 26-09-2026 | |
Ei2110 |
Ei Electronics Ei2110 User Guide (User instructions), @I559I4 |
24 | 0.25 Mb | 245 | 40 | 16-06-2026 |
Ei170RF |
Ei170RF (Smoke Alarm ePDF User Guide, #7554X6) |
8 | 0.95 Mb | 1123 | 259 | 10-10-2026 |
Ei100L |
User Guide: Ei Electronics Ei100L (467C54, Upd.23-06-2026) |
2 | 0.11 Mb | 994 | 150 | 23-06-2026 |
Ei 225E |
Ei Electronics Smoke Alarm User instructions (File: PDF, 03-09-2026) |
6 | 0.14 Mb | 964 | 145 | 03-09-2026 |
Ei171RF |
#4JFH8Z: Ei171RF Smoke Alarm User instructions |
12 | 0.19 Mb | 870 | 148 | 01-10-2026 |
Ei151TL |
Smoke Alarm #3EVIP8 |
3 | 590 | 107 | 16-08-2026 | |
Ei 220E |
PDF User Manual (@874NC4), Ei Electronics Ei 220E Smoke Alarm (04-10-2026) |
6 | 0.13 Mb | 52 | 13 | 04-10-2026 |