Sharp R-24ST Service Manual

Text of Sharp R-24ST Service Manual

R-24ST/R-2B34 - 1

SHARP CORPORATION SERVICE MANUAL R R-24ST R-2B34(AL/K/W/ST) S9110524STEHW In interests of user-safety the oven should be restored to its original condition and only parts identical to those specified should be used. MICROWAVE OVEN MODELS CAUTION, MICROWAVE RADIATION.................................................................................................... 2 GENERAL INFORMATION......................................................

R-24ST/R-2B34 - 2

CAUTION MICROWAVE RADIATION Personnel should not be exposed to the mircowave energy which may radiate from the magnetron or other microwave generating devices if it is improperly used or connected. All input and output micro- wave connections, waveguides, flanges and gaskets must be secured. Never operate the device with- out a microwave energy absorbing load attached. Never look into an open waveguide or antenna while the device is ene

R-24ST/R-2B34 - 3

APPEARANCE VIEW OPERATING SEQUENCE FUNCTION OF IMPORTANT COMPONENTS TROUBLESHOOTING CHART TEST PROCEDURE TOUCH CONTROL PANEL COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE MICROWAVE MEASUREMENT TEST DATA AT A GLANCE WIRING DIAGRAM PARTS LIST WARNING Never operate the oven until the following points are ensured. (A) The door is tightly closed. (B) The door and oven hinges are not defective. (C) The door packing is not damaged. (D) The door

Sharp R-24ST R-24ST/R-2B34 - 4

REMEMBER TO CHECK 3D 1) Disconnect the supply. 2) Door opened, and wedged open. 3) Discharge high voltage capacitor. WARNING AGAINST THE CHARGE OF THE HIGH- VOLTAGE CAPACITOR The high-voltage capacitor remains charged about 60 seconds after the oven has been switched off. Wait for 60 seconds and then short-circuit the connection of the high-voltage capacitor (that is, of the connecting lead of the high-voltage rectifier) against the chass

R-24ST/R-2B34 - 5

E RECUERDE LA COMPROBACION 3D 1) Desconecte la alimentación. 2) Deje la puerta abierta y calzada. 3) Descargue el condensador de alto voltaje. ADVERTENCIA SOBRE LA CARGA DEL CONDENSADOR DE ALTO VOLTAJE El condensador de alto voltaje permanece cargado unos 60 segundos después de haber apagado el horno. Espere 60 segundos y luego ponga en cortocircuito la conexión del condensador de alto voltaje (esto es, del conductor de conexión del r

R-24ST/R-2B34 - 6

SERVICING I TRE OPERAZIONI IMPORTANTI PER INCOMINCIARE 1) Scollegare l'alimentazione elettrica. 2) Verificare che la porta sia bloccata in posizione aperta. 3) Scaricare il condensatore ad alta tensione. ATTENZIONE AL CONDENSATORE AD ALTA TENSIONE: PUO ESSERE CARICO Il condensatore ad alta tensione rimane carico per circa 60 secondi dopo lo spegnimento del forno. Occorre quindi spettare 60 secondi prima di cortocircuitare, utilizzando

R-24ST/R-2B34 - 7

SPECIFICATION ITEM DESCRIPTION Power Requirements 230 Volts 50 Hertz Single phase, 3 wire earthed Power Consumption 1.2 kW Power Output 800W watts nominal of RF microwave energy (measured by way of IEC 60705) Operating frequency of 2450 MHz Case Dimensions Width 449mm Height 282mm including foot Depth 366mm(R-24ST) Dept 346mm(R-2B34) Cooking Cavity Dimensions Width 287mm Height 220mm Depth 311mm Turntable diameter 272mm Control Compl

Sharp R-24ST R-24ST/R-2B34 - 8

APPEARANCE VIEW OVEN 1. Place the roller stay on the floor of the oven cavity, engaging shaft into turntable motor shaft. 2. Then place the turntable on roller stay. Turntable Seal packing CONTROL PANEL Roller stay 1 Digital Display 2 Indicators The appropriate indicator will flash or light up, just above each symbol according to the instruction. When an indicator is flashing, press the suitable button (having the same symbol) or do th

R-24ST/R-2B34 - 9

NOTE: The ON/OFF time ratio does not exactly correspond to the percentage of microwave power, because approx. 3 seconds are needed for heating up the magnetron filament. Function sequence Figure 0-2 on page 29 6. MONITOR SWITCH CIRCUIT The monitor switch (SW2) is mechanically controlled by oven door, and monitors the operation of the monitored latch switch (SW1) 6-1 When the oven door is opened during or after the cycle of a cooking progr

R-24ST/R-2B34 - 10

FUNCTION OF IMPORTANT COMPONENTS FUSE F1 1. The fuse F1 also blows when the H.V. rectifer, H.V. wire harness, H.V. capacitor, magnetron or secondary winding of power transformer is shorted. 2. If the wire harness or electrical components are short- circuited, the fuse F1 blows to prevent an electric shock of fire hazard. HVT THERMOSTAT (150°C OFF ~ 96°C ON) The thermostat protects the magnetron against overheat- ing. If this temperatur

R-24ST/R-2B34 - 11

TROUBLESHOOTING CHART When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the “Test Procedure” section. IMPORTANT: If the oven becomes inoperative because of a blown fuse F. Check the monitored latch switch and monitor sw

R-24ST/R-2B34 - 12

A MAGNETRON TEST CARRY OUT 3D CHECK Isolate the magnetron from high voltage circuit by removing all leads connected to the filament terminal. To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron filament terminals, the meter should show a reading of less than 1 ohm. To test for a short circuit filament to anode condition, connect ohmmeter between one of the filament terminals and the case o

Sharp R-24ST R-24ST/R-2B34 - 13

6. Measure the final water temperature. (Example: The final temperature T2 = 21°C) 7. Calculate the microwave power output P in watts from above formula. Initial temperature T1 = 11°C Temperature after (52+ 3) = 55 sec. ............................................................................. T2 = 21°C Temperature difference Cold-Warm............................................................................ ∆T1 = 10°C Meas

R-24ST/R-2B34 - 14

CARRY OUT 3D CHECKS Isolate the switch to be tested and using an ohmmeter check between the terminals as described in the following table. TEST PROCEDURES E SWITCH TEST COM; Common terminal NO; Normally open terminal NC; Normally close terminal Table: Terminal Connection of Switch Plunger Operation COM to NO COM to NC Released Open circuit Short circuit Depressed Short circuit Open Circuit If incorrect readings are obtained, or repla

R-24ST/R-2B34 - 15

PROCEDURE LETTER COMPONENT TEST CARRY OUT 3D CHECKS 1. If the fuse F1is blown, there could be shorts or grounds in electrical parts or wire harness. Check them and replace the defective parts or repair the wire harness. CAUTION: Only replace special fuse F1 with the correct value replacement. CARRY OUT 3D CHECKS Disconnect the leads from the terminals of the thermal cut-out. Then using an ohmmeter, make a continuity test across the two t

R-24ST/R-2B34 - 16

TEST PROCEDURES The touch control panel consists of circuits including semiconductors such as LSI, ICs, etc. Therefore, unlike conventional microwave ovens, proper maintenance can not be performed with only a voltmeter and ohmmeter. In this service manual, the touch control panel assembly is in one unit and troubleshooting by unit replacement is described according to the symptoms indicated. Control Panel. The following symptoms ind

R-24ST/R-2B34 - 17

TEST PROCEDURES Remove the outer case and check voltage between Pin No 5 of the 3 pin connector (A) and common terminal of the relay (RY2) on the control unit with an A.C. voltmeter. The meter should indicate rated voltage, if not check oven circuit. RY1 and RY2 Relay Test These relays are operated by D.C. voltage Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation. DC. voltage indicated......

R-24ST/R-2B34 - 18

TOUCH CONTROL PANEL ASSEMBLY OUTLINE OF TOUCH CONTROL PANEL 4) Relay Circuit To drive the magnetron, fan motor, turntable motor and light the oven lamp. 5) Buzzer Circuit The buzzer is responsive to signals from the LSI to emit audible sounds (tact switch touch sound and completion sound). 6) Synchronizing Signal Circuit The power source synchronizing signal is available in order to compose a basic standard time in the clock circuit.

Sharp R-24ST R-24ST/R-2B34 - 19

1-12 SEG0 - OUT Segment data signal. SEG11 Connected to LCD. The relation between signals are as follows: LSI signal (Pin No.) LCD segment LSI signal (Pin No.) LCD segment SEG 0 (1) ................................ S6 SEG 6 (7)........................... S12 SEG 1 (2) ................................ S7 SEG 7 (8)............................. S5 SEG 2 (3) ................................ S8 SEG 8 (9)............................. S4 SEG 3