Sharp R-24ST Service Manual
Text of Sharp R-24ST Service Manual
R-24ST/R-2B34 - 1
SHARP CORPORATION
SERVICE MANUAL
R
R-24ST
R-2B34(AL/K/W/ST)
S9110524STEHW
In interests of user-safety the oven should be restored to its original
condition and only parts identical to those specified should be used.
MICROWAVE OVEN
MODELS
CAUTION, MICROWAVE RADIATION.................................................................................................... 2
GENERAL INFORMATION......................................................
R-24ST/R-2B34 - 2
CAUTION
MICROWAVE RADIATION
Personnel should not be exposed to the mircowave energy which may radiate from the magnetron or
other microwave generating devices if it is improperly used or connected. All input and output micro-
wave connections, waveguides, flanges and gaskets must be secured. Never operate the device with-
out a microwave energy absorbing load attached.
Never look into an open waveguide or antenna while the device is ene
R-24ST/R-2B34 - 3
APPEARANCE VIEW
OPERATING SEQUENCE
FUNCTION OF IMPORTANT
COMPONENTS
TROUBLESHOOTING CHART
TEST PROCEDURE
TOUCH CONTROL PANEL
COMPONENT
REPLACEMENT AND
ADJUSTMENT PROCEDURE
MICROWAVE MEASUREMENT
TEST DATA AT A GLANCE
WIRING DIAGRAM
PARTS LIST
WARNING
Never operate the oven until the following points are ensured.
(A) The door is tightly closed.
(B) The door and oven hinges are not defective.
(C) The door packing is not damaged.
(D) The door
Sharp R-24ST R-24ST/R-2B34 - 4
REMEMBER TO CHECK 3D
1) Disconnect the supply.
2) Door opened, and wedged open.
3) Discharge high voltage capacitor.
WARNING AGAINST THE CHARGE OF THE HIGH-
VOLTAGE CAPACITOR
The high-voltage capacitor remains charged about 60
seconds after the oven has been switched off. Wait for 60
seconds and then short-circuit the connection of the
high-voltage capacitor (that is, of the connecting lead of
the high-voltage rectifier) against the chass
R-24ST/R-2B34 - 5
E
RECUERDE LA COMPROBACION 3D
1) Desconecte la alimentación.
2) Deje la puerta abierta y calzada.
3) Descargue el condensador de alto voltaje.
ADVERTENCIA
SOBRE
LA
CARGA
DEL
CONDENSADOR DE ALTO VOLTAJE
El condensador de alto voltaje permanece cargado unos
60 segundos después de haber apagado el horno. Espere
60 segundos y luego ponga en cortocircuito la conexión
del condensador de alto voltaje (esto es, del conductor
de conexión del r
R-24ST/R-2B34 - 6
SERVICING
I
TRE OPERAZIONI IMPORTANTI PER
INCOMINCIARE
1)
Scollegare l'alimentazione elettrica.
2)
Verificare che la porta sia bloccata in posizione
aperta.
3)
Scaricare il condensatore ad alta tensione.
ATTENZIONE AL CONDENSATORE AD ALTA
TENSIONE: PUO ESSERE CARICO
Il condensatore ad alta tensione rimane carico per
circa 60 secondi dopo lo spegnimento del forno.
Occorre quindi spettare 60 secondi prima di
cortocircuitare, utilizzando
R-24ST/R-2B34 - 7
SPECIFICATION
ITEM
DESCRIPTION
Power Requirements
230 Volts
50 Hertz
Single phase, 3 wire earthed
Power Consumption
1.2 kW
Power Output
800W watts nominal of RF microwave energy
(measured by way of IEC 60705)
Operating frequency of 2450 MHz
Case Dimensions
Width 449mm
Height 282mm including foot
Depth 366mm(R-24ST)
Dept 346mm(R-2B34)
Cooking Cavity Dimensions
Width 287mm
Height 220mm
Depth 311mm
Turntable diameter
272mm
Control Compl
Sharp R-24ST R-24ST/R-2B34 - 8
APPEARANCE VIEW
OVEN
1. Place the roller stay on the floor of
the oven cavity, engaging shaft into
turntable motor shaft.
2. Then place the turntable on roller
stay.
Turntable
Seal packing
CONTROL PANEL
Roller stay
1
Digital Display
2
Indicators
The appropriate indicator will flash or light up,
just above each symbol according to the
instruction. When an indicator is flashing, press
the suitable button (having the same symbol)
or do th
R-24ST/R-2B34 - 9
NOTE: The ON/OFF time ratio does not exactly correspond
to the percentage of microwave power, because
approx. 3 seconds are needed for heating up the
magnetron filament.
Function sequence Figure 0-2 on page 29
6. MONITOR SWITCH CIRCUIT
The monitor switch (SW2) is mechanically controlled by
oven door, and monitors the operation of the monitored
latch switch (SW1)
6-1
When the oven door is opened during or after the cycle
of a cooking progr
R-24ST/R-2B34 - 10
FUNCTION OF IMPORTANT COMPONENTS
FUSE F1
1. The fuse F1 also blows when the H.V. rectifer, H.V. wire
harness, H.V. capacitor, magnetron or secondary
winding of power transformer is shorted.
2. If the wire harness or electrical components are short-
circuited, the fuse F1 blows to prevent an electric shock
of fire hazard.
HVT THERMOSTAT (150°C OFF ~ 96°C ON)
The thermostat protects the magnetron against overheat-
ing. If this temperatur
R-24ST/R-2B34 - 11
TROUBLESHOOTING CHART
When troubleshooting the microwave oven, it is helpful to
follow the Sequence of Operation in performing the checks.
Many of the possible causes of trouble will require that a
specific test be performed. These tests are given a procedure
letter which will be found in the “Test Procedure” section.
IMPORTANT:
If the oven becomes inoperative because of
a blown fuse F. Check the monitored latch
switch and monitor sw
R-24ST/R-2B34 - 12
A
MAGNETRON TEST
CARRY OUT 3D CHECK
Isolate the magnetron from high voltage circuit by removing all leads connected to the filament terminal.
To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron
filament terminals, the meter should show a reading of less than 1 ohm.
To test for a short circuit filament to anode condition, connect ohmmeter between one of the filament
terminals and the case o
Sharp R-24ST R-24ST/R-2B34 - 13
6. Measure the final water temperature. (Example: The final temperature T2 = 21°C)
7. Calculate the microwave power output P in watts from above formula.
Initial temperature T1 = 11°C
Temperature after (52+ 3) = 55 sec. ............................................................................. T2 = 21°C
Temperature difference Cold-Warm............................................................................ ∆T1 = 10°C
Meas
R-24ST/R-2B34 - 14
CARRY OUT 3D CHECKS
Isolate the switch to be tested and using an ohmmeter check between the terminals as described in the
following table.
TEST PROCEDURES
E
SWITCH TEST
COM;
Common terminal
NO;
Normally open terminal
NC;
Normally close terminal
Table: Terminal Connection of Switch
Plunger Operation
COM to NO
COM to NC
Released
Open circuit
Short circuit
Depressed
Short circuit
Open Circuit
If incorrect readings are obtained, or repla
R-24ST/R-2B34 - 15
PROCEDURE
LETTER
COMPONENT TEST
CARRY OUT 3D CHECKS
1. If the fuse F1is blown, there could be shorts or grounds in electrical parts or wire harness. Check them
and replace the defective parts or repair the wire harness.
CAUTION: Only replace special fuse F1 with the correct value replacement.
CARRY OUT 3D CHECKS
Disconnect the leads from the terminals of the thermal cut-out. Then using an ohmmeter, make a
continuity test across the two t
R-24ST/R-2B34 - 16
TEST PROCEDURES
The touch control panel consists of circuits including semiconductors such as LSI, ICs, etc. Therefore,
unlike conventional microwave ovens, proper maintenance can not be performed with only a voltmeter
and ohmmeter.
In this service manual, the touch control panel assembly is in one unit and troubleshooting by unit
replacement is described according to the symptoms indicated.
Control Panel.
The following symptoms ind
R-24ST/R-2B34 - 17
TEST PROCEDURES
Remove the outer case and check voltage between Pin No 5 of the 3 pin connector (A) and common
terminal of the relay (RY2) on the control unit with an A.C. voltmeter.
The meter should indicate rated voltage, if not check oven circuit.
RY1 and RY2 Relay Test
These relays are operated by D.C. voltage
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated......
R-24ST/R-2B34 - 18
TOUCH CONTROL PANEL ASSEMBLY
OUTLINE OF TOUCH CONTROL PANEL
4) Relay Circuit
To drive the magnetron, fan motor, turntable motor and
light the oven lamp.
5) Buzzer Circuit
The buzzer is responsive to signals from the LSI to emit
audible sounds (tact switch touch sound and completion
sound).
6) Synchronizing Signal Circuit
The power source synchronizing signal is available in
order to compose a basic standard time in the clock
circuit.
Sharp R-24ST R-24ST/R-2B34 - 19
1-12
SEG0 -
OUT
Segment data signal.
SEG11
Connected to LCD.
The relation between signals are as follows:
LSI signal (Pin No.)
LCD segment
LSI signal (Pin No.)
LCD segment
SEG 0 (1) ................................ S6
SEG 6 (7)........................... S12
SEG 1 (2) ................................ S7
SEG 7 (8)............................. S5
SEG 2 (3) ................................ S8
SEG 8 (9)............................. S4
SEG 3