ABB TTF300 Operating Instruction

Text of ABB TTF300 Operating Instruction

ABB MEASUREMENT & ANALYTICS | OPERATING INSTRUCTION

TTF300 Field-mount temperature transmitter Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy — TTF300 Introduction The TTF300 is available with the HART, PROFIBUS PA and FOUNDATION Fieldbus communication protocols. The TTF300 has global approvals for explosion protection up to Zone 0. Safety-relevant applications up to SIL 3 (redundant)

TTF300 FIELD-MOUNT TEMPERATURE TRANSMITTER | OI/TTF300-EN REV. G

Table of contents Change from one to two columns 1 Safety .......................................................................... 4 General information and instructions .................................. 4 Warnings .................................................................................... 4 Intended use .......................................................................
TTF300 FIELD-MOUNT TEMPERATURE TRANSMITTER | OI/TTF300-EN REV. G 3 10  Commissioning ........................................................ 39 General ..................................................................................... 39 Checks prior to commissioning .......................................... 39 Communication ...................................................................... 39 HART® Communication .............................
TTF300 FIELD-MOUNT TEMPERATURE TRANSMITTER | OI/TTF300-EN REV. G 1 Safety General information and instructions These instructions are an important part of the product and must be retained for future reference. Installation, commissioning, and maintenance of the product may only be performed by trained specialist personnel who have been authorized by the plant operator accordingly. The specialist personnel must have read and understood the manual and m
TTF300 FIELD-MOUNT TEMPERATURE TRANSMITTER | OI/TTF300-EN REV. G 5 Intended use This device is intended for the following uses: • To measure the temperature of fluid, pulpy or pasty substances and gases or resistance/voltage values. The device has been designed for use exclusively within the technical limit values indicated on the name plate and in the data sheets. • The maximum ambient temperature must not be exceeded. • The IP rating of the hous
TTF300 FIELD-MOUNT TEMPERATURE TRANSMITTER | OI/TTF300-EN REV. G Change from two to one column 2 Use in potentially explosive atmospheres in accordance with ATEX and IECEx hange from one to two columns Ex marking Note • Further information on the approval of devices for use in potentially explosive atmospheres can be found in the explosion protection test certificates (at www.abb.com/temperature). • Depending on the design, a specific marking in
TTF300 FIELD-MOUNT TEMPERATURE TRANSMITTER | OI/TTF300-EN REV. G 7 IECEx intrinsic safety Approved for use in Zone 0, 1, and 2. Model TTF300-H1H IECEx certificate of conformity IECEx PTB 09.0014X Model TTF300-H1P and TTF300-H1F IECEx certificate of conformity IECEx PTB 11.0108X Ex ia IIC T6...T1 Ga Ex [ia IIC Ga] ib IIC T6...T1 Gb Ex [ia IIIC Da] ib IIC T6...T1 Gb IECEx dust explosion protection Approved for use in Zone 21 and 22. Model TTF300-J5H IECEx
TTF300 FIELD-MOUNT TEMPERATURE TRANSMITTER | OI/TTF300-EN REV. G … 2 Use in potentially explosive atmospheres in accordance with ATEX and IECEx Temperature data Transmitter ATEX / IECEx intrinsic safety, ATEX non-sparking Temperature class Permissible ambient temperature range Device category 1 use Device category 2 / 3 use T6 −50 to 44 °C (−58 to 111.2 °F) −50 to 56 °C (−58 to 132.8 °F) T4 to T1 −50 to 60 °C (−58 to 140.0 °F) −5
TTF300 FIELD-MOUNT TEMPERATURE TRANSMITTER | OI/TTF300-EN REV. G 9 Type of protection flameproof (enclosure) Ex db IIC Supply circuit Maximum voltage US = 30 V Maximum current Is = 32 mA, limited by the upstream fuse (rated fuse current 32 mA) Measurement current circuit Maximum voltage UO = 6.5 V Maximum current IO = 17.8 mA Maximum power PO = 39 mW Dust explosion protection type of protection Ex tb IIIC T135°C Db, Ex tc IIIC T135°C Dc Non-intrinsica
TTF300 FIELD-MOUNT TEMPERATURE TRANSMITTER | OI/TTF300-EN REV. G … 2 Use in potentially explosive atmospheres in accordance with ATEX and IECEx Installation instructions ATEX / IECEx The installation, commissioning, maintenance and repair of devices in potentially explosive atmospheres must only be carried out by appropriately trained personnel. Works may be carried out only by persons, whose training has included instructions on different types of

ABB Transmitter Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated For Device
TTF200

ABB Transmitter Operating instruction (File: PDF, 10-07-2026)

36 901 181 10-07-2026 view all
Endura ACA592

#XM5Y76: Endura ACA592 Transmitter Operating instructions manual

94 354 71 30-05-2026 view all
4680

PDF User Manual (@16MIPC), ABB 4680 Transmitter (23-08-2026)

20 899 207 23-08-2026 view all
4623

PDF User Guide (@7YNN6H), ABB 4623 Transmitter (25-04-2026)

32 1010 213 25-04-2026 view all
LMT100

PDF User Guide (@W2PBFZ), ABB LMT100 Transmitter (16-04-2026)

84 683 130 16-04-2026 view all
Navigator 540

ABB Transmitter Instruction manual (File: PDF, 12-07-2026)

54 1270 204 12-07-2026 view all
TTF350

User Guide: ABB TTF350 (L24CJB, Upd.09-06-2026)

304 1437 216 09-06-2026 view all
LST300 Series

ABB LST300 Series User Guide (Operating instruction), @88T6UN

60 96 22 22-08-2026 view all
LWT300 series

#7YZWA9: LWT300 series Transmitter Operation & user’s manual

92 1148 265 10-04-2026 view all